Black sheath
Grey sheath
Cut the cables so that they protrude from the guide by about 5 mm, insert the guide in its plug and crimp
with the specially provided tool.
Make sure that the grey sheath stays inside the plug.
This type of connection will NOT guarantee double insulation.
POWER SUPPLY
The 1717/31 or /33 monitor can be supplied power in two different ways:
POE
24 V
– 18 W power supply
When the power supply is used, POE is not available because the monitor is powered only by the local
power supply. In this case, RJ45 can be connected to the NO POE port of the switch.
INSTALLATION
It is possible to fi x the wall bracket by using a 503 box and the supplied screws, or a Ø 60 box with suitable
screws.
Connect any panic function, extra ring tone, fl oor call, auxiliary power and link to IPerHOME system
function wires to the terminals on the external printed circuit.
Connect the monitor to the connector CN1 on the printed circuit board via the cable provided on the
back of the monitor.
Move the monitor close to the bracket by centring the special fi xings 1 and slide it down to reach its
stop 2 (see the following image).
DS1717-015B
Wire
No.
1
White-Orange
2
Orange
1
3
White-Green
4
Blue
8
~ 5 mm
1
8
Box
503
Cable colour
Plug
1
8
Wire
Cable colour
No.
5
White-Blue
6
Green
7
White-Brown
8
Brown
Box
Ø 60 mm