HPE FlexFabric 5710 Series Installation Manual page 15

Hide thumbs Also See for FlexFabric 5710 Series:
Table of Contents

Advertisement

Figure 11 Attaching the mounting brackets and chassis rails to an HPE 5710-54HF switch
(mounting brackets installed near the power supply side)
Figure 12 Attaching the mounting brackets and chassis rails to an HPE 5710-54HT switch
(mounting brackets installed near the power supply side)
Figure 13 Attaching the mounting brackets and chassis rails to an HPE 5710-30HT switch
(mounting brackets installed near the power supply side)
Connecting the grounding cable to the chassis
CAUTION:
Select grounding points as required. The primary grounding point and auxiliary grounding point are
located on the left side panel. If you use one of these grounding points, you must connect the
grounding cable to the grounding point before you mount the switch in the rack.
This section uses the primary grounding point on the HPE 5710-54HF switch as an example.
To connect the grounding cable to a grounding point:
Choose a grounding point. As a best practice, use the grounding point close to the mounting
1.
brackets.
Unpack the grounding cable and grounding screws.
2.
You can use the cable and screws shipped with the switch for connecting to the primary
grounding point or auxiliary grounding point.