10-SAFETY DEVICES OF THE MACHINE

10.1 Blade Guards

Both the top and bottom taping units have a blade
guard. (See Manual 2: AccuGlide™ 3 Taping
Heads - 2 inch).
WARNING
To reduce the risk associated with sharp
blade hazards:
Keep hands and fi ngers away from tape
cutoff blades under orange blade guards.
The blades are extremely sharp.
10.2 Emergency Stop Button
The box drive belts are turned on and off with the
electrical switch on the side of the machine frame.
The machine electrical supply can be turned off
by pressing the latching emergency stop switch.
To restart machine, rotate the emergency stop
switch clockwise to release the switch latch
(Figure 10-1). Restart machine by Pushing the On/
Off switch to the Off (O) position and then to the On
(I) position .
WARNING
To reduce the risk associated with
hazardous voltage:
− Position electrical cord away from foot
and vehicle traffi c.
Figure 10-1
200a-NA

10.3 Electric System

The electric system is protected by a ground wire
whose continuity has been tested during the fi nal
inspection. The system is also subject to insulation
and dielectric strength tests.
WARNING
To reduce the risk associated with
mechanical and electrical hazards:
− Allow only properly trained and qualifi ed
personnel to operate and service this
equipment.
Note: The case sealer has a circuit breaker
located in the electrical enclosure on the machine
frame. If circuit becomes overloaded and circuit
breaker trips, unplug the machine electrical
cord and determine cause of overload. After two
minutes, reset the circuit breaker. Plug machine
electrical cord into outlet and restart machine by
pushing the On/Off switch to the On (O) position.
Important: The use of an extension cord is not
recommended. However, if one is needed
for temporary use, it must:
Have a wire size of 1.5mm diameter [AWG 16]
Have a maximum length of 30.5m [100 ft]
Be properly grounded.