Chattanooga Neo Stimulation Channel 1 & 2 Installation Instructions
Chattanooga Neo Stimulation Channel 1 & 2 Installation Instructions

Chattanooga Neo Stimulation Channel 1 & 2 Installation Instructions

Advertisement

Quick Links

0086
Neo Stimulation
Channel 1 & 2 and
Channel 1 & 2 + EMG
Module Manual
Installation
Instructions
For complete User Operating Instructions,
including Cautions, Warnings, Dangers,
Indications, and Contraindications, refer to the
User's Manuals.
Domestic Market, US only, refer to Vectra Neo
Clinical Therapy System User Manual, Item
#13-7646 (CD Version, item #13-7647).
International Market, refer to Intelect Neo
Clinical Therapy System User Manual, Item
#13-7651 (CD Version, item #13-7652).
To obtain a copy, contact your local
representative or DJO Customer Care.
DJO, LLC
A DJO Global Company
1430 Decision Street
Vista, CA 92081-8553
T: 1-800-592-7329 USA
T: 1-760-727-1280
F: 1-760-734-5608
DJOGlobal.com
© 2017 DJO, LLC. All rights reserved.
Neo Stim Channel 1 & 2 + EMG Module
13-8905 Rev F

Advertisement

loading

Summary of Contents for Chattanooga Neo Stimulation Channel 1 & 2

  • Page 1 Neo Stimulation Channel 1 & 2 and Channel 1 & 2 + EMG Module Manual Installation Instructions For complete User Operating Instructions, including Cautions, Warnings, Dangers, Indications, and Contraindications, refer to the User’s Manuals. • Domestic Market, US only, refer to Vectra Neo Clinical Therapy System User Manual, Item #13-7646 (CD Version, item #13-7647).
  • Page 2 Neo Stimulation Channel 1 & 2 + EMG Module Manual MODULE INSTALLATION Install module from the left side (when facing the screen) 3. The second slot is illustrated below, but the technique of the unit. is the same for all modules. The Neo Stimulation Channel 1 & 2 + EMG Module is designed only for use with Vectra Neo or Intelect Neo Therapy Systems.
  • Page 3 Neo Stimulation Channel 1 & 2 + EMG Module Manual MODULE INSTALLATION (CON’T) 6. Using a #2 Phillips screwdriver, secure the module Cable Insertion with the provided 8-32 x 5/16” screw at the bottom Shown below is the Cable Insertion location tab, as shown. 7. Insert the faceplate with connection openings, For complete User Operating Instructions, including supplied with module, on the Left side at the bottom Cautions, Warnings, Dangers, Indications, and and snap into place at the top as shown. Insert a Contraindications, refer to the respective User’s Manuals. blank faceplate on the Right side. • Domestic Market, US only, refer to Vectra Neo Clinical Therapy System User Manual, item #13-7646 (CD Version, item #13-7647).
  • Page 4 Neo Stimulation Channel 1 & 2 + EMG Module Manual • Contaminated electrodes and leadwires can lead to infection. CAUTION • Use of electrode with degraded hydro-gel can result in infection to the skin burn. • This unit should be operated at 10°C to 45°C and 0% to 90% Relative Humidity. • Use of electrode on multiple patients can lead to infection. The unit should be transported and stored at 0°C to 60°C and 0% to 95% Relative • Stop treatment immediately if patient experiences discomfort or pain.