Putting the unit into service

Safety

Important! The following example of how to mount the auto-transformer onto the trolley
is for a combination of an MW 2200 power source, an FK 2200 cooling unit and an
"Easy" trolley. To put together any other combination, proceed analogously.
Mounting the
fixing brackets to
the trolley
Fig.5
Mounting the
system
components on
the trolley
Fig.6
WARNING! Work that is not carried out correctly can cause serious injury and
damage. The actions described below may ONLY be carried out by skilled,
Fronius-trained technicians! Observe and follow the "Safety rules" in the
"Operating Instructions" manual for the power source.
CAUTION! Danger from the trolley toppling over. The - relatively heavy - auto-
transformer must always be mounted as the bottom unit on the trolley. This
favourable centre-of-gravity position reduces the risk of the trolley toppling over.
Mounting the fixing brackets
Mounting the system components
1.
Turn the trolley upside-down, standing
it on its handles, then hold it in the
vertical.
2.
Use a sharp pointed tool to pierce the
rubber mat where it lies over the holes
in the baseplate
3.
Turn the trolley over and place it on its
wheels again
4.
Attach each fixing bracket to the
baseplate with 3 screws
Stack the system components on top of
one another, fixing each unit to the one
below it (and the auto-transformer to the
trolley) with 4 screws.
Important! When mounting the power
source, take care with the connector to the
cooling unit. Do not subject the cable
connection to tensile strain.
5