Cisco 6130 NI-1 Conversion Procedure page 32

Upgrade kit
Table of Contents

Advertisement

Cisco 6130 NI-1 to NI-2 Conversion Procedures
Attach the Cisco 6130 Power Connections
Note
If you do not have 12 AWG wire installed, it will be necessary to replace the wire from the
Cisco 6130 power connections and the fuse and alarm panel.
To prevent the system from powering up, do not install the fuses at this time. If the fuses
Caution
are already installed in the fuse and alarm panel, remove them. You can replace the fuses
after the system is wired.
Note
Connect each Cisco 6130 with NI-2 system component to a separate fuse. Do not power
the components in the rack by chaining them together.
Step 1
Reconnect the wires that connect the Cisco 6130 chassis to the fuse and alarm panel (POS RTN and
NEG DC connections) as shown in Figure 6 (dual-power feed) and Figure 7 (single-power feed).
These wires were removed in the "Disconnect the Cisco 6130 Power Connections" section on page 24.
Step 2
Use a socket driver or a Phillips-head screwdriver to attach the clear cover over the Cisco 6130
power connections.
Note
Cisco 6130 NI-1 to NI-2 Upgrade Kit Conversion Procedures
32
Figure 6 and Figure 7 show the wires looped through a ferrite. If you use thicker
wire, it will not be necessary to loop the wire through the ferrite. Looping the wire
secures the ferrite.
78-10709-03