4. MONITOR SPECIFICATION
MELSEC GOT
Sequence program example
Always ON
[
[
F
R
O
M H O
HE3 K4M48 K1
Remote input (RX) read
Initial setting execution program
3
Refer to Section 4.5.1
Error
status flag
H0503 Dl00
'
Command data storage
MOV HOE54 Dl04
GOT request flag ON
(command execution)
GOT complete flag
M48 (ON at processing complete)
(
~
[
R
S
T
Other command execution program
Always ON
/
[
T
O
H O
HI63 K4M148 K1
Remote output (RY) write