9. Troubleshooting

Problem
Motor won't run
Motor won't run in
Auto mode
Reduced suction
power
Extractor won't pick
up wet substance
Cause
Fuse blown in mains socket.
Overload protection triggered.
Motor defective.
Electrical appliance defective
or not connected properly.
Low power consumption of
electrical appliance.
Suction control turned down
too low.
Suction hose/nozzle clogged.
Disposal bag or dust bag full.
Fine particle filter dirty.
Seal between container and
top of extractor housing
defective or not there.
«Free-Filter-System» mecha-
nism defective.
Activation button for the filter
cleaning function is pressed
due to coiled cable.
Dust retainer full.
Reactivate mains fuse.
Turn off dust extractor and allow to cool down
for 5 minutes. Contact the Renfert Service
Team if the extractor still fails to restart.
If the extractor is to be situated in a base cabi-
net, ensure there is sufficient air cooling.
Have Renfert Service Team replace the motor.
Check operability of electrical appliance and
check if connector is tight.
Note that the min. rated power consumption is
P > 20 W.
Set suction control as described in "Suction
control adjustment".
Clean suction hose/nozzle.
See section "Replacing the disposal bag, dust
bag.
See section "Cleaning the fine particle filter",
"Replacing the fine particle filter".
Replace seal.
Contact Renfert Service Team.
Wind the cable up so that the activation button
is not actuated.
Turn off unit. Empty dust retainer.