Vortex compact 3L
Nr. 2924-5000 / -6000
Bedienungsanleitung
Instruction manual • Mode d'emploi
Istruzioni per l'uso • Instrucciones de servicio
Инструкция по эксплуатации
操作说明书 • 取扱説明書 • 사용 설명서
Ideas for dental technology
Made in the EU

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Vortex compact 3L and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Renfert Vortex compact 3L

  • Page 1 Vortex compact 3L Nr. 2924-5000 / -6000 Bedienungsanleitung Instruction manual • Mode d’emploi Istruzioni per l’uso • Instrucciones de servicio Инструкция по эксплуатации 操作说明书 • 取扱説明書 • 사용 설명서 Ideas for dental technology Made in the EU...
  • Page 4: Table Of Contents

    ENGLISH Contents Introduction Introduction We are very pleased with your decision to purchase ...................... Symbols our mobile lab dust extractor Vortex compact 3L........................ Before putting the device into operation, Operating Instructions please read these operating instructions 1. Unpack ......................
  • Page 5: Operating Instructions

    Operating Instructions 1. Unpack 3.2 Insert cloth filter and disposal bag • Remove the unit and its accessories from its pack- aging. Instead of a dustbag it is possible to use a cloth filter • Open holding clamps and remove top from ex- together with a disposal bag (see accessories).
  • Page 6: Extension Cord

    3.8 Cleaning the fine filter „Free- 3.4.1 e xtension cord Only use an extension cord that at least complies Filter-System“ with or exceeds OEM specifications. Check that the When suction begins to be less powerful: cord has the correct minimum cross section: • Set selector to „I“ (maximum power). Cord length Cross-section •...
  • Page 7: Replace Dust Bag

    • Fold top edge of disposal bag over edge of dust retainer (Fig. 8). No. 2924-5000 Vortex compact 3L, 230 V, 50 / 60 Hz • Insert the cloth filter into the dust retainer. Ensure No. 2924-6000 Vortex compact 3L, 120 V, 60 Hz the position is correct (Fig.
  • Page 8: Troubleshooting

    • If the extractor is to be situated in a base cabi- net, ensure there is sufficient air cooling. • Motor defective. • Have Renfert Service Team replace the motor. Motor won‘t run in • Electrical appliance defective • Check operability of electrical appliance and Auto mode.
  • Page 9: Operator's Notes

    The unit is suitable for commercial use, e.g. in dental Before making further use of the unit, have labs. the Renfert Service Team or a skilled electri- cian replace the broken mains lead. When used properly, the safety vacuum cleaner described in this manual is suitable...
  • Page 10: Admitted Persons

    Use OEM spare parts and accessories sup- For more information regarding proper disposal plied by Renfert GmbH only. please apply at your local authorities. Environmentally hazardous extraction sub- stances.
  • Page 11: Non-Liability Clause

    800 hrs. • product repairs are not made by specialised Renfert gives you a 3-year warranty on all parts of dealers or if repairs are not made with OEM Vortex compact 3L, assuming the unit is used as spare parts supplied by Renfert;...
  • Page 12 Tel.: +49 7731 82 08-0 • Fax: +49 7731 82 08-70 www.renfert.com • info@renfert.com Renfert USA • 3718 Illinois Avenue • St. Charles IL 60174/USA Tel.: +1 6307 62 18 03 • Fax: +1 6307 62 97 87 Ideas for dental technology www.renfert.com •...