Testing
It is easy to test the Bellman Visit 868 Smoke Alarm. If the Smoke Alarm does not work as described below,
you can check further under Troubleshooting/Troubleshooting guide.
How to test
Test the Smoke Alarm at least once per month and preferably each week, e.g. during cleaning. Always test it
immediately after any holidays or other extended periods of absence.
A receiver in the Bellman Visit 868 System which is set to the same Radio Key as the Smoke Alarm is
required to test the Smoke Alarm with the Test Button (2) or by blowing in smoke. Proceed as follows:
• Press the Test Button (2) until the Bellman Visit 868 Smoke Alarm starts to beep with a shrill tone and
then release the Test Button immediately.
• The Bellman Visit 868 receivers will then indicate a flat battery.
• Hold down the Test Button (2) for at least 5 seconds or blow smoke into the Smoke Alarm. The Bellman
Visit 868 Smoke Alarm will transmit a radio signal after about five to ten seconds.
• The Bellman Visit 868 receivers will then indicate the Smoke Alarm.
Troubleshooting
You can carry out a number of checks yourself before sending a product for repair.
Troubleshooting guide
Problem
Nothing happens when the transmitter is activated with the Test
Button (2).
The Bellman Visit 868 Receivers occasionally indicate a fire alarm
for no apparent reason.
The Smoke Alarm can be activated with the test button (2) but
the receivers are not responding.
The receiver signals when no transmitter is activated.
The Smoke Alarm beeps and chirps in a different way from that
indicated above for no reason.
Be1530/Be1550
Solution
• Change the battery. Use a Duracell MN1604, Energizer 522
(alkaline) or Ultralife U9VL-J (lithium).
• Change the battery. Use a Duracell MN1604, Energizer 522
(alkaline) or Ultralife U9VL-J (lithium).
• Change the Radio Key on all units in the system. For further
information see Function/Radio Key
• Check that the Smoke Alarm's antenna is straight and points to
the floor.
• Check that the receivers are not placed too far away by moving
them closer to the Smoke Alarm.
• Check the battery in the receiver.
• Check that all units in the Bellman Visit 868
System are set to the same Radio Key. For further information see
Appendix/Further information/Settings/Radio Key.
• Change the Radio Key on all units in the relevant Bellman Visit
868 System. There is probably another system nearby with the
same Radio Key.
• The Smoke Alarm is defective and needs to be sent for repair.