Bellman external Trigger Cable
Be9086
Function
The BE9086 Bellman External Trigger Cable is a connecting cable
between the BE1341 Bellman Alarm Clock and a unit that releases an
alarm pulse in the form of a voltage. Such units include the vibrator
output on a BE1450 Bellman Visit 868 Portable receiver or BE1470
Bellman Visit 868 Pager when combined with the BE1260 Bellman
Visit Charger, or a direct connection to a property's central fire alarm
system.
Stereo
Be9086
Mono
Page 193
Technical information
Output signals
Connection to alarm source: 3.5mm mono jack plug.
Contact to BE1340: 3.5mm stereo jack plug
Additional information
For indoor use only
Weight:
20 g
Colour: White
Flex length: 1.5 m
-
+
U
Input voltage circuits
DC
3 to 28 V
AC RMS
3 to 17 V