Download Print this page

Receivers - Bellman & Symfon Visit 868 BE1410 Manual

Advertisement

Technical Solutions
Bellman Visit System Information
The Bellman Visit 868 Smoke Alarm will beep once per minute while the LED (2) blinks when the battery is
becoming completely flat.
A flat battery alarm signal will then be transmitted to the Bellman Visit 868 System which causes the receivers
to briefly indicate a fire alarm at the same time as the receivers' fire alarm LED blinks once every five seconds.
Troubleshooting in brief
Problem
Nothing happens when the transmitter is activated with
the Test Button (2).
The Bellman Visit 868 receivers occasionally indicate a
fire alarm for no apparent reason.
The Smoke Alarm can be activated but the receivers are
not responding.
The receivers in the system transmit signals for no
reason.
The Smoke Alarm beeps and chirps in a different way
from that indicated above for no reason.

6

5
Solution
• Change the battery. Use a Duracell MN1604, Energizer 522 or
Ultralife U9VL-J.
• Change the battery. Use a Duracell MN1604, Energizer 522 or
Ultralife U9VL-J.
• Change the Radio Key on all units in the system. For further
information see Function/Radio key.
• Check the battery in the receiver.
• Check that the receivers are not placed too far away by moving
them closer to the Smoke Alarm.
• Check that the Smoke Alarm is set to the correct Radio Key. For
further information see Function/Radio key.
• Change the Radio Key on all units in the system. For further
information see Function/Radio key.
• The Smoke Alarm is defective and needs to be sent for repair.
1.
Antenna
2.
LED / test button
3.
Battery cover
4.
Ceiling bracket
5.
Radio key switch
6.
Broadcast switch
Be1530/Be1550