Quick Links

KOMFORT ZONE KIT
#K ZK-1510A
For use with models
#BHM-38, #BHM-44, #CLW-ST, #CLW-50,
#CLW-50-MV
English and French installation manuals are available through your local
dealer. Visit our website www.kozyheat.com.
Les manuels d'installation en français et en anglais sont disponibles chez
votre détaillant local. Visitez www.kozyheat.com .
1.0 INTRODUCTION .......................................................................3
1.1 Kit Contents.......................................................................................... 3
1.2 Fireplace Preparation ........................................................................ 3
1.3 Suggested Configurations .............................................................. 4
1.4 Dimensions and Overview ............................................................. 7
1.5 Air Duct Pipe Run ............................................................................... 8
2.0 FRAMING AND CLEARANCES ................................................9
2.1 Clearance to Sprinkler ...................................................................... 9
2.2 Framing................................................................................................10
2.3 Shelf Requirements .........................................................................14
2.4 CLW-ST Front Facing Clearances ................................................16
3.0 FACING AND FINISHING .......................................................17
3.1 Non-combustible Requirements ................................................17
3.2 Combustible Finish ..........................................................................20
3.3 Hearth and Mantel Clearances ....................................................24
4.0 INSTALLATION .......................................................................27
Hussong Manufacturing Co., Inc.
204 Industrial Park Drive, PO Box 577
Lakefield, MN 56150-0577, USA
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
READ ALL THESE STEPS BEFORE STARTING
INSTALLATION. LEAVE THESE INSTRUCTIONS
WITH THE APPLIANCE.
This kit must be installed by a qualified installer,
service agency, or gas supplier at the time of the
heater installation. These instructions must be used
in conjunction with the installation and operation
manual provided with the appliance. Please read
the appliance owner's manual completely before
performing any procedures in these instructions.
This optional convection duct kit redistributes the
warm air flow away from the fireplace opening to
a more desirable location using natural convection
without the use of a fan. The warm air flow may be
relocated to a position higher up the wall, out the
sidewalls, or even to an adjacent room. The result is
much cooler wall temperatures above the fireplace
opening for locating televisions, artwork, etc.
Rev. 9, December 2021

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the KZK-1510A and is the answer not in the manual?

Questions and answers

Summary of Contents for kozy heat KZK-1510A

  • Page 1: Table Of Contents

    KOMFORT ZONE KIT #K ZK-1510A For use with models #BHM-38, #BHM-44, #CLW-ST, #CLW-50, #CLW-50-MV INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference. READ ALL THESE STEPS BEFORE STARTING English and French installation manuals are available through your local dealer.
  • Page 3: Introduction

    1.2 Fireplace Preparation ALL kit contents must be installed. 1.2.1 BHM-38 & BHM-44 Requirements • (2) 15" plenum kit: #KZK-1510A For ease of installation, the header heat shield may be removed. • (2) air grilles The stand-off assembly still must be installed. To install stand-off •...
  • Page 4: Suggested Configurations

    SECTION 1 INTRODUCTION Suggested Configurations 1.3 Suggested Configurations When installing the #KZK-1510A, take in consideration the fireplace venting and the plenum tube configuration. The (2) plenums and the (2) air grilles in this kit are required and both must be installed.
  • Page 5 SECTION 1 INTRODUCTION Suggested Configurations CLW-ST #KZK-1510A front wall outlet Fixed/back Access/front side side FIGURE 1.5 #KZK-1510A Suggested Configuration for CLW-ST #KZK-1510A HUSSONG MFG. CO., INC. KOZY HEAT FIREPLACES R.9, December 2021...
  • Page 6 #KZK-1510A side wall outlet For side wall outlet installations, it is easier to keep the 1/2” (12mm) clearance if the center tubes are assembled to the backside of the KZK FIGURE 1.6 #KZK-1510A Suggested Configurations for BHM-44 #KZK-1510A HUSSONG MFG. CO., INC.
  • Page 7 ” ½ (304mm) ” (342mm) stando 3” (38mm) (76mm) ⁄ ” ⁄ (149mm) ” (220mm) ¾ stando (19mm) ⁄ ” 4” 6” (198mm) (102mm) (152mm) FIGURE 1.7 #KZK-1510A Dimensions #KZK-1510A HUSSONG MFG. CO., INC. KOZY HEAT FIREPLACES R.9, December 2021...
  • Page 8: Air Duct Pipe Run

    (304mm) 12” (304mm) CLW-50 & CLW-50-MV CLW-ST Minimum bend radius=6” (152mm) 4” (102mm) 12” (304mm) BHM-38 & BHM-44 FIGURE 1.8 Minimum Vent Pipe Run - only (1) plenum shown #KZK-1510A HUSSONG MFG. CO., INC. KOZY HEAT FIREPLACES R.9, December 2021...
  • Page 9: Framing And Clearances

    Please follow local building codes to determine what temperature setting is relevant for your installation. ALL MODELS 60” (1524mm) 3” Ceiling (76mm) sprinkler head FIGURE 2.1 KZK Clearance to Sprinkler #KZK-1510A HUSSONG MFG. CO., INC. KOZY HEAT FIREPLACES R.9, December 2021...
  • Page 10: Framing

    Rough opening framing dimensions should allow for wall covering thickness and facing materials. ALL MODELS Ceiling ½ 3” ” (76mm) (38mm) ½ ½ ” ” (12mm) (12mm) FIGURE 2.2 Minimum Clearances for Plenum Air Discharge to Ceiling #KZK-1510A HUSSONG MFG. CO., INC. KOZY HEAT FIREPLACES R.9, December 2021...
  • Page 11 STEEL FRAMING ½ 76” ” (1930mm) (1892mm) ¼ ” (1683mm) 22” (558mm) Dimensions reflect minimum enclosure height FIGURE 2.3 CLW-50 Rough Opening and Framing for #KZK-1510A CLW-50 & CLW-50-MV ¼ 76” ” (1930mm) (108mm) ¼ ” 48” ½ ” (108mm)
  • Page 12 (210mm) (457mm) (457mm) ½ ” (1892mm) ¼ ” (1683mm) 17” (432mm) Dimensions reflect minimum enclosure height FIGURE 2.5 CLW-ST Rough Opening and Framing for #KZK-1510A CLW-ST Ceiling/Fireplace enclosure top Single vertical header 76” (1930mm) ¼ ” (1098mm) ½ ” (1638mm) 17”...
  • Page 13 ½ ” 88” (2235mm) (2197mm) ¼ ” (1988mm) 22” (558mm) Dimensions reflect minimum enclosure height FIGURE 2.7 BHM-44 Rough Opening and Framing for #KZK-1510A BHM-44 Ceiling/Fireplace enclosure top Ceiling/Fireplace enclosure top ½ ” Double horizontal (1537mm) header TV Recess ¼...
  • Page 14 (209mm) ½ ” 88” (2235mm) (2197mm) ¼ ” (1988mm) 22” (558mm) FIGURE 2.10 BHM-38 Rough Opening and Framing for #KZK-1510A Dimensions reflect minimum enclosure height BHM-38 Ceiling/Fireplace enclosure top Ceiling/Fireplace enclosure top ½ ” Double horizontal (1537mm) header TV recess ¼...
  • Page 15: Shelf Requirements

    ¾ ” 7” (2102mm) (178mm) MIN 76” 22” (1930mm) (559mm) Grille 3” (76mm) ¾ 76” ” 18” (1930mm) (2102mm) (457mm) Enclosure Floor Enclosure Floor FIGURE 2.11 CLW-50 Shelf Requirements #KZK-1510A HUSSONG MFG. CO., INC. KOZY HEAT FIREPLACES R.9, December 2021...
  • Page 16 Grille 18” (457mm) 16” 22” (406mm) (559mm) 88” (2235mm) 0” (0mm) 18” Grille (457mm) 16” (406mm) 88” (2235mm) Enclosure Floor Enclosure Floor FIGURE 2.12 BHM-38 & BHM-44 Shelf Requirements #KZK-1510A HUSSONG MFG. CO., INC. KOZY HEAT FIREPLACES R.9, December 2021...
  • Page 17: Clw-St Front Facing Clearances

    SECTION 2 FRAMING AND CLEARANCES CLW-ST Front Facing Clearances 2.4 CLW-ST Front Facing Clearances FIGURE 2.13 below shows the front facing clearance requirements for the CLW-ST for the KZK-1510A air discharge opening. 2” (51mm) 18” (457mm) 2” (51mm) 76” (1930mm) FIGURE 2.13 CLW-ST Front Facing Clearances...
  • Page 18: Facing And Finishing

    ” ” (38mm) (248mm) No Screws Allowed No Screws Allowed No Screws Allowed ¾ 13” ” 13” ¾ ” (330mm) (95mm) (330mm) (95mm) FIGURE 3.1 Minimum Non-combustible Finishing Dimensions #KZK-1510A HUSSONG MFG. CO., INC. KOZY HEAT FIREPLACES R.8, October 2021...
  • Page 19 Non-combustible nishing material only ½ ” (1512mm) No Screws Allowed ½ ” (64mm) ¾ ½ ” ” (248mm) (38mm) No Screws Allowed FIGURE 3.2 CLW-ST Minimum Non-combustible Finishing Dimensions #KZK-1510A HUSSONG MFG. CO., INC. KOZY HEAT FIREPLACES R.8, October 2021...
  • Page 20 ⁄ ” (205mm) ⁄ ” (1072mm) ⁄ ” (633mm) ½ ” (978mm) ½ ” (64mm) Non-combustible nishing material only Combustible nishing material allowed FIGURE 3.3 Minimum Non-combustible Finishing Dimensions #KZK-1510A HUSSONG MFG. CO., INC. KOZY HEAT FIREPLACES R.8, October 2021...
  • Page 21 ⁄ ” ⁄ ” (205mm) (1148mm) ⁄ ” (633mm) ½ ” (1130mm) ½ ” (63mm) Non-combustible Combustible nishing nishing material only material allowed FIGURE 3.4 Minimum Non-combustible Finishing Dimensions #KZK-1510A HUSSONG MFG. CO., INC. KOZY HEAT FIREPLACES R.8, October 2021...
  • Page 22: Combustible Finish

    ⁄ ” (301mm) ⁄ ” (301mm) NOT ALLOWED INSIDE MINIMUM SHELF ENCLOSURE OR MINIMUM POCKET ENCLOSURE FIGURE 3.5 #KZK-1510A Drywall Finish and Combustible Finishing Material up to 1" Thick #KZK-1510A HUSSONG MFG. CO., INC. KOZY HEAT FIREPLACES R.9, December 2021...
  • Page 23 Combustible wall nish Steel up to 1” (25mm) thick Framing may be installed over non-combustible material Non-combustible material Finishing Edge Fireplace Enclosure Floor FIGURE 3.6 1" Thick Wall Finish Installation #KZK-1510A HUSSONG MFG. CO., INC. KOZY HEAT FIREPLACES R.8, October 2021...
  • Page 24 Finishing Finishing edge edge Non-combustible Non-combustible material only material only Fireplace enclosure oor FIGURE 3.7 1" Thick Wall Finish Installation #KZK-1510A HUSSONG MFG. CO., INC. KOZY HEAT FIREPLACES R.8, October 2021...
  • Page 25 Non-combustible material Top nishing edge FIGURE 3.8 1" Thick Wall Finish Installation #KZK-1510A HUSSONG MFG. CO., INC. KOZY HEAT FIREPLACES R.8, October 2021...
  • Page 26: Hearth And Mantel Clearances

    3/4" (19mm) 3/4" (19mm) CW50-RS4 2-5/8" (66mm) 2-5/8" (66mm) CW50-GS 6" (152mm) 2-1/2" (64mm) CW50-MS 3-1/8" (79mm) 3-1/8" (79mm) FIGURE 3.9 Finishing Guidelines for CLW-50 & CLW-ST Optional Surrounds #KZK-1510A HUSSONG MFG. CO., INC. KOZY HEAT FIREPLACES R.9, December 2021...
  • Page 27 6” (152mm) Finishing Edge ¾ ” (425mm) ½ ” (673mm) Finishing Edge 6” (152mm) 9” (229mm) ¾ ” (248mm) 12” (305mm) Fireplace Enclosure Floor FIGURE 3.10 Hearth and Mantel Clearances #KZK-1510A HUSSONG MFG. CO., INC. KOZY HEAT FIREPLACES R.8, October 2021...
  • Page 28 (both sides of replace) Top nishing edge ¾ ” ½ (502mm) ” (750mm) Bottom nishing edge 18” (458mm) 21” (543mm) ¾ ” (248mm) Fireplace Enclosure Floor FIGURE 3.11 Hearth and Mantel Clearances #KZK-1510A HUSSONG MFG. CO., INC. KOZY HEAT FIREPLACES R.8, October 2021...
  • Page 29 12” (305mm) 9” (229mm) 6” (152mm) Top nishing edge 25” (635mm) ½ ” (699mm) ½ ” Bottom (64mm) nishing edge 14” (356mm) Combustible oor FIGURE 3.12 Hearth and Mantel Clearances #KZK-1510A HUSSONG MFG. CO., INC. KOZY HEAT FIREPLACES R.8, October 2021...
  • Page 30: Installation

    FIGURE 4.4 CLW-ST Convection Baffles Removal - 1 Side Convection air ow with ba es removed FIGURE 4.5 BHM-38 & BHM-44 Convection Baffle Removal FIGURE 4.2 CLW-ST Air Flow inside Appliance with Convection Baffles Removed #KZK-1510A HUSSONG MFG. CO., INC. KOZY HEAT FIREPLACES R.9, December 2021...
  • Page 31 10. If desired, the air grilles may be painted. Use high temperature paint (250°F). 11. Continue with fireplace installation. FIGURE 4.8 CLW-ST Cover Plate Removal FIGURE 4.9 BHM-38 & BHM-44 Cover Plate Removal FIGURE 4.7 Air Grille Screw Location #KZK-1510A HUSSONG MFG. CO., INC. KOZY HEAT FIREPLACES R.9, December 2021...
  • Page 33 KIT KOMFORT ZONE nº K ZK-1510A Pour utiliser avec modelès BHM-38, BHM-44, CLW-50, CLW-50-MV, CLW-ST LISEZ TOUTES CES ÉTAPES AVANT DE English and French installation manuals are available through your local COMMENCER L’INSTALLATION. LAISSEZ CE dealer. Visit our website www.kozyheat.com. MANUEL AVEC L’...
  • Page 35: Introduction

    1.2 Préparation du foyer Toutes les composants de ce kit est requis et doit être installé. 1.2.1 BHM-38 et BHM-44 • (2) plénum de 15 po du kit KZK-1510A L'écran thermique du linteau n'est pas requis pour cette installation. • (2) grilles d'air Les étriers de dégagement doivent être installés.
  • Page 36: Configurations Suggérées

    SECTION 1 INTRODUCTION Configurations suggérées 1.3 Configurations suggérées CLW-50 & CLW-50-MV #KZK-1510A sortie murale arrière #KZK-1510A sortie murale adjacent FIGURE 1.4 CLW-50 Configurations suggérées du KZK-1510A KZK-1510A HUSSONG MFG. CO., INC. KOZY HEAT FIREPLACES R.9, décembre 2021...
  • Page 37 SECTION 1 INTRODUCTION Configurations suggérées CLW-ST #KZK-1510A front wall outlet Fixed/back Access/front side side FIGURE 1.5 CLW-ST Configurations suggérées du KZK-1510A KZK-1510A HUSSONG MFG. CO., INC. KOZY HEAT FIREPLACES R.9, décembre 2021...
  • Page 38 C’est plus facile de maintenir le dégagement de 1/2 po autour conduits pour l'installations sortie murale arrière si les conduits centraux sont assemblés à l'arrière de KZK FIGURE 1.6 BHM-38 et BHM-44 Configurations suggérées du KZK-1510A KZK-1510A HUSSONG MFG. CO., INC.
  • Page 39 ” (342mm) 3” dégagement (38mm) (76mm) ⁄ ” ⁄ (149mm) ” (220mm) ¾ (19mm) espaceur de dégagement ⁄ ” 4” 6” (198mm) (102mm) (152mm) FIGURE 1.7 Dimensions du KZK-1510A KZK-1510A HUSSONG MFG. CO., INC. KOZY HEAT FIREPLACES R.9, décembre 2021...
  • Page 40: Installation Des Conduit D'air

    12” (304mm) 12” (304mm) CLW-50 & CLW-50-MV CLW-ST Rayon de courbure minimal=6” (152mm) 4” (102mm) 12” (304mm) BHM-38 & BHM-44 FIGURE 1.8 Installation de conduits d'air de longueur minimale KZK-1510A HUSSONG MFG. CO., INC. KOZY HEAT FIREPLACES R.9, décembre 2021...
  • Page 41: Encadrement Et Dégagements

    Veuillez suivre les codes du bâtiment locaux pour déterminer quel réglage de température convient à votre installation. TOUS LES MODÈLES 60” (1524mm) 3” Tête de gicleur (76mm) au plafond FIGURE 2.1 Dégagement au gicleur du kit KZK KZK-1510A HUSSONG MFG. CO., INC. KOZY HEAT FIREPLACES R.9, décembre 2021...
  • Page 42: Encadrement

    (si applicable). TOUS LES MODÈLES Plafond ½ 3” ” (76mm) (38mm) ½ ½ ” ” (12mm) (12mm) FIGURE 2.2 Dégagement minimal de la sortie d'air au plafond KZK-1510A HUSSONG MFG. CO., INC. KOZY HEAT FIREPLACES R.9, décembre 2021...
  • Page 43 (1130mm) 22” 76” (559mm) ½ ” (1930mm) (1638mm) ½ ” 22” (1130mm) (559mm) Dimensions correspondant à la hauteur d’enceinte minimale FIGURE 2.4 Encadrement et dégagement pour le foyer CLW-50 KZK-1510A HUSSONG MFG. CO., INC. KOZY HEAT FIREPLACES R.9, décembre 2021...
  • Page 44 étroit vers le bas) 76” (1930mm) ¼ ” (1098mm) ½ ” (1638mm) 17” (559mm) Dimensions correspondant à la hauteur d’enceinte minimale FIGURE 2.6 Encadrement et dégagement pour le foyer CLW-ST KZK-1510A HUSSONG MFG. CO., INC. KOZY HEAT FIREPLACES R.9, décembre 2021...
  • Page 45 88” ⁄ ” (2235mm) ¼ ” (1463mm) (1175mm) 22” ¼ ” (558mm) (1175mm) Dimensions correspondant à la hauteur d’enceinte minimale FIGURE 2.8 Encadrement et dégagement pour le foyer BHM-44 KZK-1510A HUSSONG MFG. CO., INC. KOZY HEAT FIREPLACES R.9, décembre 2021...
  • Page 46 88” ⁄ (2235mm) ” (1311mm) ¼ ” (1098mm) 22” ¼ (558mm) ” (1098mm) Dimensions correspondant à la hauteur d’enceinte minimale FIGURE 2.9 Encadrement et dégagement pour le foyer BHM-38 KZK-1510A HUSSONG MFG. CO., INC. KOZY HEAT FIREPLACES R.9, décembre 2021...
  • Page 47: Dimensions D'installation Et Exigences Avec Étagère

    (178mm) MIN 76” 22” (1930mm) (559mm) Grille d’air 3” (76mm) ¾ 76” ” 18” (1930mm) (2102mm) (457mm) Plancher de l’enceinte Plancher de l’enceinte FIGURE 2.11 CLW-50 Requis d'une tablette d'étagère KZK-1510A HUSSONG MFG. CO., INC. KOZY HEAT FIREPLACES R.9, décembre 2021...
  • Page 48 (406mm) (559mm) 88” (2235mm) 0” (0mm) 18” Grille (457mm) d’air 16” (406mm) 88” (2235mm) Plancher de l’enceinte Plancher de l’enceinte FIGURE 2.12 BHM-38 & BHM-44 Requis d'une tablette d'étagère KZK-1510A HUSSONG MFG. CO., INC. KOZY HEAT FIREPLACES R.9, décembre 2021...
  • Page 49: Dégagements Aux Mur Face Avant De Clw-St

    Dégagements aux mur face avant de CLW-ST 2.4 Dégagements aux mur face avant de CLW-ST La FIGURE 2.13 ci-dessous montré les exigences de dégagements pour le CLW-ST face l'avant de l'ouverture de sortie d'air KZK-1510A, installée sur le mur face avant. 2” (51mm) 18”...
  • Page 50: Façade Et Finition

    Aucune vis permise Aucune vis permise ¾ 13” ¾ ” 13” ” (330mm) (95mm) (330mm) (95mm) FIGURE 3.1 Dimensions minimales des matériaux incombustibles de finition pour le foyer CLW-50 KZK-1510A HUSSONG MFG. CO., INC. KOZY HEAT FIREPLACES R.9, décembre 2021...
  • Page 51 Emplacement de vis acceptables Matériaux de nition incombustibles seulement ¾ ½ ” ” (248mm) (38mm) Aucune vis permise FIGURE 3.2 Dimensions minimales des matériaux incombustibles de finition pour le foyer CLW-ST KZK-1510A HUSSONG MFG. CO., INC. KOZY HEAT FIREPLACES R.9, décembre 2021...
  • Page 52 ½ ” (978mm) ½ ” (64mm) Matériaux de nition incombustibles seulement Matériaux de nition combustible permise FIGURE 3.3 Dimensions minimales des matériaux incombustibles de finition pour le foyer BHM-38 KZK-1510A HUSSONG MFG. CO., INC. KOZY HEAT FIREPLACES R.9, décembre 2021...
  • Page 53 ½ ” (1130mm) ½ ” (63mm) Matériaux de nition Matériaux de nition incombustibles seulement combustible permis FIGURE 3.4 Dimensions minimales des matériaux incombustibles de finition pour le foyer BHM-44 KZK-1510A HUSSONG MFG. CO., INC. KOZY HEAT FIREPLACES R.9, décembre 2021...
  • Page 54: Matériaux De Finition Combustibles

    (301mm) ⁄ ” (301mm) Cette installation n'est pas autorisée pour une tablette encastrée FIGURE 3.5 Revêtement en matêriau combustible et Matériaux de finition combustibles de 1 po d'épaisseur maximale KZK-1510A HUSSONG MFG. CO., INC. KOZY HEAT FIREPLACES R.9, décembre 2021...
  • Page 55 (matériau incombustible) Matériau incombustible seulement Bord de nition du foyer Plancher d’enceinte du foyer FIGURE 3.6 CLW-50 matériaux de finition murale combustibles avec le KZK-1510A KZK-1510A HUSSONG MFG. CO., INC. KOZY HEAT FIREPLACES R.9, décembre 2021...
  • Page 56 Bord de Bord de nition du foyer nition du foyer Matériaux Matériaux incombustibles incombustibles Plancher d’enceinte du foyer FIGURE 3.7 CLW-ST matériaux de finition murale combustibles avec le KZK-1510A KZK-1510A HUSSONG MFG. CO., INC. KOZY HEAT FIREPLACES R.9, décembre 2021...
  • Page 57 être installée par dessus le panneau de ciment (matériau incombustible) Matériau incombustible Bord de nition du foyer FIGURE 3.8 BHM-38 & BHM-44 matériaux de finition murale combustibles avec le KZK-1510A KZK-1510A HUSSONG MFG. CO., INC. KOZY HEAT FIREPLACES R.9, décembre 2021...
  • Page 58: Dégagements De L'âtre Et Du Manteau

    6” (152mm) ¾ 9” (229mm) ” (248mm) 12” (305mm) Plancher d’enceinte du foyer FIGURE 3.10 Dégagements de l’âtre et du manteau pour une installation sans contour pour le foyer CLW-50 KZK-1510A HUSSONG MFG. CO., INC. KOZY HEAT FIREPLACES R.9, décembre 2021...
  • Page 59 18” (458mm) 21” (543mm) ¾ ” (248mm) Plancher d’enceinte du foyer FIGURE 3.11 Dégagements de l’âtre et du manteau pour une installation sans contour pour le foyer CLW-ST KZK-1510A HUSSONG MFG. CO., INC. KOZY HEAT FIREPLACES R.9, décembre 2021...
  • Page 60 Bord de ntion (64mm) du foyer 14” (356mm) Plancher combustible FIGURE 3.12 Dégagements de l’âtre et du manteau pour une installation sans contour pour le foyer BHM-38 et BHM-44 KZK-1510A HUSSONG MFG. CO., INC. KOZY HEAT FIREPLACES R.9, décembre 2021...
  • Page 61: Installation

    Trajet de l’air de convection (dé ecteurs retirés) FIGURE 4.5 Déflecteurs de convection retiré pour le foyer BHM-38 & BHM-44 FIGURE 4.2 Débits d'air sans déflecteurs de convection pour le foyer CLW-ST KZK-1510A HUSSONG MFG. CO., INC. KOZY HEAT FIREPLACES R.9, décembre 2021...
  • Page 62 FIGURE 4.7 Retrait des couvercles pour le foyer CLW-ST sécher la peinture à 250°F. 11. Continuez l’installation du foyer. FIGURE 4.9 Installation de la grille d'air FIGURE 4.8 Retrait des couvercles pour le foyer BHM-38 et BHM-44 KZK-1510A HUSSONG MFG. CO., INC. KOZY HEAT FIREPLACES R.9, décembre 2021...

Table of Contents