P.O. BOX 557 204 INDUSTRIAL PARK DRIVE
LAKEFIELD, MINNESOTA USA 56150-0577
READ ALL THESE STEPS BEFORE STARTING INSTALLATION. LEAVE THESE INSTRUCTIONS WITH THE APPLIANCE.
This kit must be installed by a qualified installer, service agency, or gas supplier at the time of the heater installation.
These instructions must be used in conjunction with the installation and operation manual provided with the appliance.
Please read all appliance owner's manual completely before performing any procedures in these instructions.
1.0 Introduction ............................................................. 3
1.1 Kit Contents ............................................................. 3
1.2 Suggest Configurations ............................................ 4
1.3 Dimensions and Overview ....................................... 6
1.4 Air Duct Run ............................................................. 7
2.0 Framing and Clearances ........................................... 8
2.1 Clearance to Sprinkler ............................................. 8
2.2 Framing .................................................................... 9
3.0 Facing and Finishing ............................................... 12
3.1 Non-combustible Requirements ........................... 13
3.2 Finish Requirements .............................................. 15
3.3 Hearth and Mantel Clearances .............................. 18
4.0 Fireplace Preparation & Installation ....................... 20
4.1 Bellingham 38 ........................................................ 20
4.2 Nordik 41 DV.......................................................... 22
This optional convection duct kit redistributes the warm air flow away from the fireplace opening to a more desirable
location using natural convection without the use of a fan. The warm air flow may be relocated to a position higher up the
wall, out the sidewalls, or even to an adjacent room. The result is much cooler wall temperatures above the fireplace
KZK-038
Komfort Zone Kit #KZK-038
For use with Bellingham 38 (#BHM-38), and Nordik 41 DV (#NDK-41-DV)
opening for locating televisions, artwork, etc.
1
English and French installation manuals are available
through your local dealer. Visit our website
www.kozyheat.com.
Les manuels d'installation en français et en anglais sont
disponibles chez votre détaillant local. Visitez
www.kozyheat.com.
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
IMPORTANT: Failure to read and follow these instructions
may create a possible hazard and will void the fireplace
warranty.
Rev. 2 - May 2023

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the KZK-038 and is the answer not in the manual?

Questions and answers

Summary of Contents for kozy heat KZK-038

  • Page 1: Table Of Contents

    Komfort Zone Kit #KZK-038 For use with Bellingham 38 (#BHM-38), and Nordik 41 DV (#NDK-41-DV) P.O. BOX 557 204 INDUSTRIAL PARK DRIVE LAKEFIELD, MINNESOTA USA 56150-0577 READ ALL THESE STEPS BEFORE STARTING INSTALLATION. LEAVE THESE INSTRUCTIONS WITH THE APPLIANCE. This kit must be installed by a qualified installer, service agency, or gas supplier at the time of the heater installation.
  • Page 2 KZK-038 Rev. 2 — May 2023...
  • Page 3: Introduction

    ALL kit contents must be installed. • (1) KZK-410-6 (sold separately) is used for a 10' vent run. If • (1) 40" plenum kit: KZK-038 you are mounting the plenum above the fireplace 10' (3m) • or less, use (1) KZK-410-6 kit.
  • Page 4: Suggest Configurations

    When installing the #KZK-038, take in consideration the fireplace venting and the plenum tube configuration. • The #KZK-038 plenum can be installed so it discharges heat into either the room the Bellingham 38 is installed or an adjacent in-door room behind the appliance.
  • Page 5 • The #KZK-038 plenum can only discharge into the same room that the Nordik 41 DV is installed. • Figure 1.5 shows two common configurations. • The plenum discharge must be placed in the same room as the appliance. Nordik 41 DV Figure 1.4 - Nordik 41 DV Suggested Plenum Configuration...
  • Page 6: Dimensions And Overview

    1.3 Dimensions and Overview Figure 1.5 - KZK-038 Dimensions KZK-038 Rev. 2 — May 2023...
  • Page 7: Air Duct Run

    Hussong Mfg. Co., Inc. requires pipes to be listed as UL181 Class 0 Air Duct to connect the plenum(s) to the unit. Maximum Vent Run: 20’ (6m) Bellingham 38 Nordik 41 DV Figure 1.7 - Nordik 41 DV Horizontal Run Figure 1.6 - Bellingham 38 Horizontal Run KZK-038 Rev. 2 — May 2023...
  • Page 8: Framing And Clearances

    • Please follow local building codes to determine what temperature setting is relevant for your installation. Figure 2.1 - Clearance to Sprinkler KZK-038 Rev. 2 — May 2023...
  • Page 9: Framing

    Figure 2.3 & 2.4 show the minimum height of plenum framing from the base of that specific fireplace. Figure 2.2 - Plenum Framing Bellingham 38 Nordik 41 DV Figure 2.3 - Bellingham 38 Plenum Framing Figure 2.4 - Nordik 41 DV Plenum Framing KZK-038 Rev. 2 — May 2023...
  • Page 10 This applies to the Nordik 41 Figure 2.5 - Minimum Clearance to Ceiling Bellingham 38 Nordik 41 DV Figure 2.6 - Bellingham 38 Plenum Framing Figure 2.7 - Nordik 41 DV Plenum Framing KZK-038 Rev. 2 — May 2023...
  • Page 11 Bellingham 38 Figure 2.8 - Bellingham 38 Wall Enclosure Rough Opening Nordik 41 DV Figure 2.9 - Nordik 41 DV Wall Enclosure Rough Opening KZK-038 Rev. 2 — May 2023...
  • Page 12: Facing And Finishing

    IMPORTANT: The B41-PSF2 and B41-FRSF2 (Figure 3.1) are ONLY approved for use when the Nordik 41 DV is installed with the #KZK-038. The other (4) safety barriers shown in Figure 3.2 are approved in all installation scenarios. Safety Barriers Approved for All Design Options...
  • Page 13: Non-Combustible Requirements

    3.1 Non-Combustible Requirements Bellingham 38 Figure 3.3 - Bellingham 38 Minimum Non-Combustible Finishing DImensions KZK-038 Rev. 2 — May 2023...
  • Page 14 Nordik 41 DV Figure 3.4 - Nordik 41 DV Minimum Non-Combustible Finishing DImensions KZK-038 Rev. 2 — May 2023...
  • Page 15 See Figure 3.5 for finishing options. Finishing material must not block the opening and must be run evenly along the plenum opening. WARNING! RISK OF OVERHEATING AND FIRE! Ensure the KZK duct system is installed in accordance to this manual Figure 3.5 - Plenum Air Discharge Finishing Options KZK-038 Rev. 2 — May 2023...
  • Page 16: Finish Requirements

    • See Figure 3.5 on page 15 for up to 1" (25mm) thick combustible material installation around the KZK air discharge grille. Bellingham 38 Figure 3.6 - Bellingham 38 Combustible Wall Finish and Surround KZK-038 Rev. 2 — May 2023...
  • Page 17 Non-combustible material only Fireplace Top Fireplace Enclosure Floor Figure 3.7 – Nordik 41 DV Combustible Wall Finish and Surround KZK-038 Rev. 2 — May 2023...
  • Page 18: Hearth And Mantel Clearances

    The following drawings show the hearth and mantel clearances allowed for the Bellingham 38 and Nordik 41 DV. • Figure 3.8 show the mantel and hearth projections for the Bellingham 38 allowed when using this KZK-038. The image below shows the mantel projection starting at the top fireplace finishing edge and the hearth projection starting at the bottom fireplace finishing edge.
  • Page 19 • Figure 3.9 shows the mantel and hearth projections for the Nordik 41 DV allowed when using this KZK-038. The im- age below shows the mantel projection starting at the top fireplace finishing edge. • Combustible flooring can run underneath this appliance which would then allow an unlimited combustible hearth projection.
  • Page 20: Fireplace Preparation & Installation

    4. Frame the rough opening of the fireplace and KZK plenum. All contents in this kit are required and must be installed. Refer to all pages of this KZK-038 manual and the Bellingham 38 manual. See previous pages of this manual for allowable The Kozy Zone Kit requires that the convection baffle, lo- plenum positions and rough frame opening sizes.
  • Page 21 Figure 4.4 - Trim Installation Figure 4.3 - Stand-Off and Heat Shield Installation KZK-038 Rev. 2 — May 2023...
  • Page 22: Nordik 41 Dv

    6. Frame the rough opening of the fireplace and KZK plenum. Refer to is secured with (4) sheet metal screws. See the sec- all pages of this KZK-038 manual and the Nordik 41 DV manual. See ond image in Figure 4.5. Discard these cover plates.
  • Page 23 IMPORTANT: The B41-PSF2 and B41-FRSF2 (Figure 3.1) are ONLY Shield Installation approved for use when the Nordik 41 DV is installed with the #KZK-038. The other (4) safety barriers shown in Figure 3.2 are approved in all installation scenarios. Figure 4.9 - Trim Installation Figure 4.7 - Nordik 41 Air Flow with Plates Removed...
  • Page 24 KZK-038 Rev. 2 — May 2023...
  • Page 25 Komfort Zone Kit #KZK-038 À utiliser avec Bellingham 38 (#BHM-38) et Nordik 41 DV (#NDK-41-DV) P.O. BOX 557 204 INDUSTRIAL PARK DRIVE LAKEFIELD, MINNESOTA USA 56150-0577 LISEZ TOUTES CES ÉTAPESAVANT DE COMMENCER L’INSTALLATION. LAISSEZ CE MANUEL AVEC L’ APPAREIL. Ce kit doit être installé par un centre de service ou un installateur qualifié, ou par le fournisseur de gaz, au moment d’in- staller l’appareil de chauffage.
  • Page 26 KZK-038 Rev. 2 — May 2023...
  • Page 27: Introduction

    1.1 Contenu du kit TOUT le contenu du kit doit être installé. • • (1) Ensemble plénum 40" : KZK-038 (1) KZK-410-6 (vendu séparément) est utilisé pour une course de ventilation de 10'. Si vous montez le plénum au-dessus du •...
  • Page 28: Configurations Suggérées

    Lors de l'installation du #KZK-038, tenez compte de la ventilation du foyer et de la configuration du tube du plénum. • Le plénum #KZK-038 peut être installé de manière à évacuer la chaleur soit dans la pièce où le Bellingham 38 est installé, soit dans une pièce adjacente à l'intérieur de la porte derrière l'appareil.
  • Page 29 • Le plénum #KZK-038 ne peut décharger que dans la même pièce où le Nordik 41 DV est installé. • La figure 1.5 montre deux configurations courantes. • Le plénum d'évacuation doit être placé dans la même pièce que l'appareil.
  • Page 30: Dimensions Et Vue D'ensemble

    1.3 Dimensions et vue d'ensemble Figure 1.5 - KZK-038 Dimensions KZK-038 Rev. 2 — May 2023...
  • Page 31: Chemin Du Conduit D'air

    Hussong Mfg. Co., Inc. exige que les tuyaux soient répertoriés comme conduit d'air UL181 classe 0 pour connecter le(s) plé- num(s) à l'unité. Course maximale de l'évent : 20’ (6 m) Bellingham 38 Nordik 41 DV Figure 1.7 - Course horizontale Nordik 41 DV Figure 1.6 - Course horizontale Bellingham 38 KZK-038 Rev. 2 — May 2023...
  • Page 32: Encadrement Et Dégagements

    • Veuillez suivre les codes du bâtiment locaux pour déterminer quel réglage de température est pertinent pour votre installation. Figure 2.1 - Dégagement à l'arroseur KZK-038 Rev. 2 — May 2023...
  • Page 33: Encadrement

    à partir de la base de ce foyer spécifique. Figure 2.2 - Charpente du plénum Bellingham 38 Nordik 41 DV Figure 2.3 - Cadre de plénum Bellingham 38 Figure 2.4 - Cadre de plénum Nordik 41 DV KZK-038 Rev. 2 — May 2023...
  • Page 34 à partir du haut du foyer. Ceci s'applique au Nordik 41 DV. Figure 2.5 - Dégagement minimum au plafond Bellingham 38 Nordik 41 DV Figure 2.6 - Cadre de plénum Bellingham 38 Figure 2.7 - Cadre de plénum Nordik 41 DV KZK-038 Rev. 2 — May 2023...
  • Page 35 Bellingham 38 Figure 2.8 - Ouverture brute de l'enceinte murale Bellingham 38 Nordik 41 DV Figure 2.9 - Ouverture brute de l'enceinte murale Nordik 41 DV KZK-038 Rev. 2 — May 2023...
  • Page 36: Parement Et Finition

    IMPORTANT : Les modèles B41-PSF2 et B41-FRSF2 (Figure 3.1) sont UNIQUEMENT approuvés pour une utilisation lorsque le Nordik 41 DV est installé avec le #KZK-038. Les (4) autres barrières de sécurité illustrées à la figure 3.2 sont approuvées dans tous les scénarios d'installation.
  • Page 37: Non Combustibles

    3.1 Exigences non combustibles Bellingham 38 Figure 3.3 - Bellingham 38 Dimensions minimales de finition incombustibles KZK-038 Rev. 2 — May 2023...
  • Page 38 Nordik 41 DV Figure 3.4 - Nordik 41 DV Dimensions minimales de finition incombustibles KZK-038 Rev. 2 — May 2023...
  • Page 39: Exigences De Finition

    être acheminé uniformément le long de l'ouverture du plénum. AVERTISSEMENT! RISQUE DE SURCHAUFFE ET D'INCENDIE ! Assurez-vous que le système de conduits KZK est installé con- formément à ce manuel Figure 3.5 - Options de finition de décharge d'air plénum KZK-038 Rev. 2 — May 2023...
  • Page 40 Voir Figure 3.5 à la page 39 pour une installation de matériaux combustibles jusqu'à 1 po (25 mm) d'épaisseur autour de la grille d'évacuation d'air KZK. Bellingham 38 Figure 3.6 - Bellingham 38 Combustible Wall Finish and Surround KZK-038 Rev. 2 — May 2023...
  • Page 41 Voir Figure 3.5 à la page 39 pour une installation de matériaux combustibles jusqu'à 1 po (25 mm) d'épaisseur autour de la grille d'évacuation d'air KZK. Nordik 41 DV Figure 3.7 - Finition et contour de mur combustibles Nordik 41 DV KZK-038 Rev. 2 — May 2023...
  • Page 42: Dégagements Du Foyer Et Du Manteau

    La figure 3.8 montre les projections du manteau et de l'âtre pour le Bellingham 38 autorisées lors de l'utilisation de ce KZK-038. L'image ci-dessous montre la projection du manteau commençant au bord de finition supérieur du foyer et la projection de l'âtre commençant au bord de finition inférieur du foyer.
  • Page 43 La figure 3.9 montre les projections du manteau et de l'âtre pour le Nordik 41 DV autorisées lors de l'utilisation de ce KZK-038. L'image ci-dessous montre la projection du manteau à partir du bord de finition supérieur du foyer. Un revêtement de sol combustible est autorisé...
  • Page 44: Préparation Et Installation Du Foyer

    4. Encadrez l’ouverture brute du foyer et du plénum KZK. Reportez- Tout le contenu de ce kit est requis et doit être installé. vous à toutes les pages de ce manuel KZK-038 et du manuel Bel- lingham 38. Voir les pages précédentes de ce manuel pour les Le kit Kozy Zone nécessite que le déflecteur de convection,...
  • Page 45 Figure 4.4 - Installation de la garniture Figure 4.3 - Installation de l'entretoise et de l'écran thermique KZK-038 Rev. 2 — May 2023...
  • Page 46: Nordik 41 Dv

    Voir la première image de la Figure 4.5. 5. Encadrez l’ouverture brute du foyer et du plénum KZK. Re- portez-vous à toutes les pages de ce manuel du KZK-038 et du 2. Retirez les (4) plaques de recouvrement là où chaque manuel du Nordik 41 DV.
  • Page 47 IMPORTANT : Les modèles B41-PSF2 et B41-FRSF2 (Figure 3.1) sont UNIQUEMENT approuvés pour une utilisation lorsque le Nordik 41 DV est installé avec le #KZK-038. Les (4) autres barrières de sécurité Figure 4.8 - Installation de l'entretoise et de illustrées à la figure 3.2 sont approuvées dans tous les scénarios l'écran thermique Nordik 41...

Table of Contents