5.3 Connection to the extraction system
Before using the machine, it is necessary to connect an external extraction system to the two
suction outlets located at the rear of the machine on the fixed protective guards, as shown in
the figure below.
Figure 8 – Outlet for the extraction system on the guard
5.4 Connecting the power plug and start-up test (Art. 0552)
1. Insert the power plug into a power
outlet with a grounding wire.
2. Start the machine by pressing the
green switch I (see Figure 11) and
make sure that the rotating direction of
the equipment is consistent with that
indicated by the arrows marked on the
protective casing (caps).
3. Before starting the grinding, check the mounted wheels as follows:
making them rotate freely for at least 5 minutes at a peripheral operating speed;
with the guards closed and without the presence of personnel.
Impact from projected parts
During the test run, no operator and no other person should be within range of the machine.
Page 16 of 33
Figure 9 – Close-up of power plug.
MACHINES AND
ACCESSORIES