2.1.4 Wiring the Power Inputs

The upper panel of the Industrial Serial Server indicates a DC inlet power socket and consists of one terminal block connector
within 6 contacts. Please follow the steps below to insert the power wire.
Insert positive/negative DC power wires into Contacts 1 and 2 for Power 1, or Contacts 5 and 6 for Power 2. Figure 2-1-3
1.
and 2-1-4 show PWR1 and PWR2 of the Industrial Serial Server.
ICS-2200T: 12~48V DC
ICS-2400T: 12~48V DC
2.
Tighten the wire-clamp screws for preventing the wires from loosening.
User's Manual of IGS-2x00T Serial Device Server Series
Figure 2-1-3 ICS-2200T Upper Panel
Figure 2-1-4 ICS-2400T Upper Panel
1
2
3
V1+
V1-
Power 1
Fault
Figure 3-3 PWR1 & PWR2 pin of terminal block.
18
4
5
6
V2+
V2-
Power 2