4.5.2.6 TCP Client mode

The TCP client initiates a connection to the server on the network. You must set up the target IP address and assigned local port
number of server that you want the client to communicate with. In the data transmission phase, the data is transmitted to the
destination in the order to which they are sent. INDUSTRIAL SERIAL SERVER device supports four sets of sequential
connections. The TCP client mode topology in
The TCP client mode screenshot in
Object
• TCP Keep-alive
Interval
• Quiescent Time
• Max connection
• Local TCP port
User's Manual of IGS-2x00T Serial Device Server Series
Figure 4-5-22
appears.
Figure 4-5-22: TCP Client Mode Topology
Figure 4-5-23
appears.
Figure 4-5-23: TCP Client Mode Screenshot
Description
TCP keep alive interval shows how many seconds the unit waits during an inactive
connection before checking its status. If the unit does not receive a response, it will drop
that connection. The default is 0 minute.
When the network connection is determined to be idle, the duration of the control
network inactivity will cause the connection to be forced closed. The range of value is
from 1 to 65535 ms. The default is 0 ms
This parameter set the TCP port number on which it will listen for the connection and set
the maximum (up to two) acceptable number of connections. The range of value is from
1 to 4. The default is 1.
This parameter describes the TCP port that communicates with the connected device.
The setting slave and master destination IP parameters must use the same value to