Page 1
PORTABLE INVERTER GENERATOR GEN6600W240VS 120/240V IMPORTANT ─READ AND UNDERSTAND THE MANUAL PRIOR TO USING, KEEP MANUAL FOR REFERENCE. 2019-1-18 (REV:01)
C O N T E N T S SAFETY INFORMATION ............................... 2 CONTROL & FEATURES .............................. 4 PRE-OPERATION CHECK ............................6 OPERATION ..................................8 PERIODIC MAINTENANCE ............................11 TROUBLE SHOOTING ............................... 14 STORAGE..................................15 SPECIFICATION ................................16 WIRING DIAGRAM ..............................17...
WARNING PLEASE READ AND UNDERSTAND THIS MANUAL COMPLETELY BEFORE OPERATING THE GENERATOR SAFETY INFORMATION EXHAUST FUMES ARE POISONOUS Never operate the engine in a closed area or it may cause unconsciousness or death within a short period of time. Operate the engine in a well ventilated area.
Page 4
CONNECTION NOTES Do not connect the generator to commercial power outlet. Do not connect the generator in parallel with any other generator. SAFETY SYMBOLS Caution - The user should be aware of a general hazard. Dangerous Voltage Flammable Hot Surface - Do not touch.
CONTROL & FEATURES (1) Spark plug (2) Fuel tank (3) Fuel tank cap (4) Fuel filter (5) Carrying handle (6) Fuel level gauge (7) Muffler (8) Battery (9) Air filter (10) Brake lever (11) Wheel (12) Oil filler cap (13) Oil drain plug (14) AC pilot light (15) Overload indicator light (16) Oil warning light...
Page 6
OIL WARNING SYSTEM FIG.2 When the oil level falls below the lower level, the engine stops automatically. Unless you refill with oil, the engine will not start again. FIG.2 ENGINE SWITCH The engine switch controls the ignition system. FIG.3 ① RUN(on) Ignition circuit is switched on.
OUTPUT RESET FIG.7 Push reset button for 2 seconds, the generator will recover the AC output when the generator stop producing AC output under overload protect. FIG.7 MODE NOTE: Reduce the load on the generator to ensure that the total load is within the generator’s rated output power.
Page 8
CHECK ENGINE OIL FIG.10 Make sure the engine oil is indicated by dip stick at the upper level of the oil filler hole. Add oil as necessary. FIG.10 Remove oil filler cap and check the engine oil level. If oil level is below the lower level line, refill with suitable oil to upper level line.
OPERATION FIG.14 NOTE: The generator has been shipped without engine oil. Fill with oil or it will not start. Do not tilt the generator when adding engine oil. This could result in overfilling and damage to the engine. FIG.15 MODE STARTING THE ENGINE...
Page 10
Be sure the outlet load current is within outlet’s rated current. FIG.20 The economy control switch must be turned to “OFF” when using electric devices that require a large starting current, such as a compressor or a submersible pump. FIG.20 OVERLOAD INDICATOR LIGHT FIG.21 The overload indicator light comes on when overloaded, short circuit, or voltage...
Page 11
(c) If DC breaker has popped or open, disconnect the device then press to reset and reconnect DC device. CAUTION: Be sure the economy control switch is turned off while charging the FIG.24 battery. FIG.25 STOPPING THE ENGINE 1. Turn off the power switch of the electric device or disconnect any electric devices.
PERIODIC MAINTENANCE MAINTENANCE CHART Regular maintenance is important for the best performance and safe operation. Pre-operation Initial Every Every Every Item Remarks check 1 months 3 months 6 months 12 months (daily) or 20 Hr or 50Hr or100Hr or 300Hr Spark Check condition adjust gap and ...
Page 13
ENGINE OIL REPLACEMENT FIG.28 Place the generator on a level surface and warm up the engine for several minutes. Then stop the engine and turn the fuel cock knob to OFF. Turn the fuel tank cap air vent knob clockwise. Loosen the screw and remove the cover.
Page 14
CAUTION: FIG.31 The engine should never run without the element; excessive piston and/or cylinder wear may result. CLEANING AND ADJUSTING SPARK PLUG 1. Remove the cover. 2. Check for discoloration and remove the carbon. FIG.31 3. Check the spark plug type and gap. 4.
Use a flathead screw driver to pry the spark arrester out from the muffler. Remove the carbon deposits on the muffler screen and spark arrester FIG.34 using a wire brush. FIG.34 Re-install the muffler screen. Re-install the cover TROUBLE SHOOTING ENGINE WON’T START 1.
STORAGE Long term storage of your generator will require some preventive procedures maintenance to guard against deterioration. DRAIN THE FUEL Remove the fuel tank cap, drain the fuel from the fuel tank Remove the cover, drain fuel from the carburetor by loosening the drain screw. ENGINE Remove the spark plug, pour in about one tablespoon of SAE 10W30 or 20W40 motor oil into the spark plug hole and reinstall the spark plug.
SPECIFICATION MODEL GEN6600W240VS Type Inverter Generator AC Voltage 120/240V Frequency 60Hz Max. Output 6.6 kW Continuous Output 6 kW Power Factor DC Output POWER OUTLET 12V / 5.0A / USB 5V/3.1A Model XY188F-1 Type Air-cooled, 4 cycle, OHV, Gasoline Engine Bore×Stroke...