Power Consumption Examples Per Enclosure - IBM Storwize V5100 MTM 2078-424 Quick Installation Manual

Table of Contents

Advertisement

Table 27. Power specifications per power supply (continued)
Model and type
2077-92F, 2077-
A9F
2078-92F, 2078-
A9F
Note: One or more C19 power distribution units (PDU) are needed in the rack to connect power to
2078-92F, 2078-A9F power supplies.
The power and thermal measurements that are shown in Table 28 on page 102 were obtained in the
specific operating environment and under the conditions described. These measurements are presented
as an illustration; measurements that are obtained in other operating environments might vary. Conduct
your own testing to determine specific measurements for your environment.
Table 28. Power consumption examples per enclosure
Model and type
2077/2078-12F or 2077/2078-24F or
2077/2078-AFF
102 Storwize V5100 : Quick Installation Guide for MTM 2078-424, 2078-12F, 2078-24F, 2078-92F, and 2078-
U5B
Input power
PSU
requirements
AC 200-240
V~ ,
(nominal; +/-
10% tolerant)
2400 W (2)
50/60 Hz
(nominal;
47-63 Hz
tolerant)
1 enclosure with 24 2.5-inch
flash drives
Maximum input
current
12 A (x2 - per
inlet
redundancy)
Requires an IEC
C20 appliance
coupler
(16-20A branch
circuit or C19
power socket
PDU)
Configuration
Maximum
Caloric value
power output
(BTU/hr)
2400W
8189
Total power consumption
151 W