Release Notes
Polycom® QDX 6000™, Version 4.0.1.1
Category
Issue ID
Interoperability
BROAD-2523
Polycom RMX 2000
Version 7.x
Interoperability
BROAD-978
Polycom VSX
Interoperability
BROAD-1147
Sony PCS-XG80
Interoperability
BROAD-1146
Sony PCS-XG80
Interoperability
BROAD-1139
Tandberg MXP
Interoperability
BROAD-829
FX
Interoperability
BROAD-361
Tandberg MXP
Hardware
BROAD-914
Multicast
BROAD-1097
TV UI
BROAD-793
Camera
BROAD-1087
Camera
BROAD-965
Interoperability
BROAD-1185
Polycom RMX 2000
Interoperability
BROAD-1183
Tandberg MXP
Found in
Descriptions
Release
microphone might change the system's
mute status.
4.0.1
When QDX 6000 is in a call with RMX
2000 running 7.1.0.121 or later version,
the received video resolution and frame
rate on QDX 6000 may be lower than that
RMX transmits.
4.0.1
In SIP calls to the Polycom VSX system,
QDX 6000 does not negotiate transmitting
stereo audio.
4.0.1
Sony PCS-XG80 is unable to send H.239
content to QDX 6000 when connecting to
high resolution content source.
4.0.1
Occasionally, QDX 6000 crashes when the
Sony PCS-XG80 sends content when
connecting to high resolution content
source.
4.0.1
Call rates higher than 1920 kbps will
down-speed to 1920 kbps when QDX
6000 makes a SIP call with Tandberg
MXP.
4.0.0
People+Content does not work in calls
between Polycom QDX 6000 and FX.
4.0.0
Encryption check codes on Tandberg MXP
and QDX 6000 do not match.
4.0.1
The RS-232 Flow Control is not supported
when the RS-232 mode is set to Pass
Thru.
4.0.1
System pop up an error dialog "cannot
create overlay" while reopening the
multicast page.
4.0.0
When 802.1x is enabled on the system,
the EAP authentication status does not
update if the LAN cable is disconnected.
4.0.1
Occasionally, the EagleEye camera as the
nd
2
camera shows blue screen.
4.0.1
Sometimes the 2nd PTZ camera cannot
be detected automatically.
4.0.1
In SIP calls with Polycom RMX2000,
Polycom QDX 6000 receives H.263 4CIF
video instead of H.264 1024x576 video at
call rate of 768 kbps.
4.0.1
In HD calls with Tandberg MXP, the lip
sync of Polycom QDX 6000 is slightly off.
9
Workaround
mute status.
Disable H.264 on QDX 6000.
Use call rates lower than 384 kbps
(including 384 kbps), or higher than
768 kbps.
Reduce the resolution of Sony
content to 1280x720 or lower.
Reduce the resolution of Sony
content to 1280x720 or lower.
None
None
None
None
Close the web browser and reopen.
None
Manually detect the EagleEye
camera.
Manually detect the EagleEye
camera.
1. Let QDX dial into RMX2000;
2. Use call rate other than 768 kbps.
None
Need help?
Do you have a question about the QDX 6000 and is the answer not in the manual?
Questions and answers