DISASSEMBLY
Prior to performing this, be sure all pressure is re-
moved from the system.
1. Remove the retaining cap. Push down on the coil
while prying the nameplate/retainer cover in the
direction of the arrow [
Nameplate/retainer cover will slip forward, releas-
ing the coil assembly. Slip the coil assembly and
spring washer off of the solenoid base subas-
sembly.
2. Unscrew solenoid base sub-assembly from
manual operator body.
3. Unscrew manual operator body from valve body.
Then remove body gasket and stem retainer.
4. All parts are now accessible for cleaning or re-
placement.
REASSEMBLY
1. Lubricate all gaskets with Dow Corningr
Compound lubricant, or equivalent high-grade sil-
icone grease. If replacing parts, exchange worn or
damaged parts with new parts found in the replac-
ment kit, and/or replacement coil.
2. Position core assembly with core spring into base
of manual operator body.
spacer sub-assembly into manual operator body
to engage with core assembly.
3. Reinstall stem retainer on body and stem/spacer
sub-assembly.
NOTE
See Figure 7-7.The spacer on the stem/spacer sub-
assembly must be outside of the stem retainer for
external spring construction.
4. Replace body gasket and install manual operator
assembly in valve body. Torque manual operator
body to 175 ± 25 in-lbs (19.8 ± 2.8 Nm).
5. Replace solenoid base gasket and solenoid base
sub-assembly. Torque solenoid base sub-assem-
bly to 175 ± 25 in-lbs (19.8 ± 2.8 Nm).
Figure 7-7 Solenoid Valve (P/N 02250044-392)
External Spring Type Solenoid-
Spacer Location
] (See Figure 7-6).
111
Then install stem/
7.7.7 CONTROL PRESSURE REGULATOR (P/N
SPACER
STEM
RETAINER
MAINTENANCE
6. Check manual operator for proper operation. Turn
stem clockwise and couterclockwise; stem should
turn freely without binding.
Figure 7-8 Pressure Regulator (P/N 02250100-362)
*Replacement Kit P/N 02250122-521
02250100-362) MAINTENANCE
Refer to Figure 7--8. Maintenance for this control
pressure regulator normally requires the replace-
ment of the internal diaphragm, o--ring, and dia-
phragm gasket.
Use replacement
02250122-521, and follow the procedure below for
proper installation.
WARNING
!
DO NOT remove caps, plugs, and/or other compo-
nents when compressor is running or pressurized.
Stop compressor and relieve all internal pressure
before doing so.
NOTE
When replacing parts, always visually inspect
those parts that are not included with the kit. If
these parts show wear, consult Sullair factory.
1. Loosen the locknut and turn the adjusting screw
counterclockwise until the inner spring tension is
relieved. The adjusting screw should turn freely
when the spring tension is relieved.
2. Remove the spring chamber from the body to allow
access to internal parts.