Section 7
MAINTENANCE
Figure 7-1 Air Filter (P/N 048456)
*Replacement Element P/N 048462
** Replacement Element P/N 048463
6. Replace secondary element with new element.
7. Replace primary element with new element.
8. Replace clover and tighten retaining band.
7.7.2 OIL FILTER MAINTENANCE
Refer to Figure 7--2. Oil filter maintenance (using re-
pair kit P/N 02250049--820) should be performed at
8,000 hours, one year or when the corresponding
maintenance message is displayed by the Supervi-
sor II -- this corresponds to a pressure loss condition
across the unit of 20 psig (1.4 barg). Your oil filter in-
cludes a proprietary replaceable element (P/N
02250049--821) available solely from Sullair and its
agents -- DO NOT substitute.
1. Using a strap wrench, remove the old element and
gasket.
2. Clean the gasket seating surfaces.
3. Apply a light film of fresh oil to the new gasket and
hand--tighten new element until gasket contacts
the seat.
4. Continue tightening element by hand, an addition-
al 1/2 to 3/4 turn.
5. Restart package and check for leaks.
7.7.3 CONTROL LINE FILTER MAINTENANCE
Refer to Figure 7--3. Control line filter (P/N
02250112-032) maintenance normally requires re-
placement of the filter element, float assembly and
seals. Use repair kit no. 02250112-031 (filter ele-
28
RETAINING CLIP
Figure 7-2 Oil Filter (P/N 02250049-820)
*Replacement Element P/N 02250049-821