Specification
The N8551-28F/N8151-44F Built-In AIT has the following specification:
Performance
Memory capacity
Bit error code
Data transfer speed (TAPE)
Burst data transfer speed (SCSI)
Initialize time
Load time
Unload time
Rewind time
Environmental requirement
During operation
During non-operation
Power supply specification
Voltage
Current (Typ.)
Current (Max.)
50 Gbyte (In the compression mode: 100 Gbyte) when
using AIT2 Data Cartridge: tape length 230 m
35 Gbyte (In the compression mode: 70 Gbyte) when using
AIT1 Data Cartridge: tape length 230 m
25 Gbyte (In the compression mode: 50 Gbyte) when using
AIT1 Data Cartridge: tape length 170 m
The value in the compression mode is obtained when the
compression efficiency is X2.
The compression efficiency varies with the data pattern.
-17
10
or less
6 Mbyte/second (in the non-compression mode)
40 Mbyte/second (max, synchronous)
Less than 5 seconds
Less than 14 seconds
Less than 20 seconds
Less than 105 seconds
Temperature: 5 °C to 35 °C
Humidity: 20% to 80% (no dew condensation allowed)
Highest dry bulb temperature: 26 °C
Temperature: -40 °C to 70 °C
Humidity: 10% to 90% (no dew condensation allowed)
5V±5%
12V±10%
1.5A
0.4A
2.5A
1.2A