Figure 3-14 Installing Hall effect sensors
Step 4 Install an adapter.
1.
2.
3.
4.
Issue 07 (2019-01-02)
Install an adapter when the CIM communicates over the COM port.
Prepare ST3.5x35 tapping screws, washers, and 6x30 plastic expansion sleeves by yourself.
Mark mounting holes using markers.
Drill holes using a hammer drill.
Knock 6x30 plastic expansion sleeves into the mounting holes using a rubber mallet.
Secure the adapter using ST3.5x35 tapping screws and washers to a torque of 0.3 N· m.