Maintenance - HCL Smart Band SM-FT-1000 Operation, Parts And Safety Manual

Banding tool
Hide thumbs Also See for Smart Band SM-FT-1000:
Table of Contents

Advertisement

B A N D I N G

Maintenance

For maintenance of air ratchets please
see manufacturers manual
RED MARKER
1
Wind the square drive clockwise until red marker is
showing
2
Tap square drive on rear of tool to ensure rear housing is
as far forward as possible. This will aid the removal of the
bolts
3
Remove M8 Buttonhead screws (4x) using 5mm Allen key
4
Remove internal sub-assembly
5
Wind the square drive anti-clockwise to remove threaded
shaft from internal housing. Thoroughly clean all parts.
Apply Silicone grease to male and female threads as
shown
SM-FT-1000 Banding Tool
T O O L I N G
TOOL BACK
S E C T I O N
6
6
Remove M4 Capscrews and Full nuts (4x each) from split
housing. Thoroughly clean all parts
7
Apply Silicone grease to thrust washers and split housing
as shown
8
Remove M6 Capscrew and slide front assembly off main
body. Thoroughly clean all parts
9
Grease Cam and blade as shown