IMPORTANT – Input pressure should be greater than
0.6 MPa but less than 1.0 MPa
– Input hose size should be ½" and above
Ensure Pressure Dial
on Ratchet Wrench
is set to 'HI' at all
times
3
To set required pressure, pull down Pressure
regulator knob until orange band appears,
then twist until dial shows required pressure,
finally, click knob back up until orange band
Lockable Shut-Off Valve
7
Set Lockable shut-off valve to 'SUP.' to supply
air to the tool. To shut-off the air supply to the
tool and dump the excess pressure in the hose
to atmosphere, set Lockable shut-off valve to
'EXH.' (this enables safe removal of the hose).
S E C T I O N
6
7
4

Pressure Regulator

disappears.
5
B A N D I N G
Pressure
Regulation
1
Pressure Regulator Gauge
2
Air Filter –
input
8
3
Pressure Regulator Knob
4
Air Lubricator
5
Lubrication Dial
6
Lubrication Fill-point
7
Lockable Shut-Off Valve
8
5m hose
Air Lubricator
5
6
To fill lubricator, remove black cap
using 5mm Allen key and fill to
between the maximum and minimum
oil levels. See air ratchet manual for
suitable oils. Ensure lubricator dial is
set to '2' at all times.