KDK K40DSH2NET Operating Instructions Manual page 12

Compact axial flow fan
Table of Contents

Advertisement

Installation Instructions
Connecting wiring
K25DSF2NET
(The illustration shows an example of connecting for high
power operation. For low power operation, connect cords
according to the "Wiring Diagram" on page 11.)
Power
supply
Protection tapes or covers for insulation
Connecting wiring
1.Insert power cords into the terminal left-side holes as shown below figures.
2.Fasten each screws firmly, and check to pull softly and not to be pulled off or moved.
3.After that, secure power cord with the nylon clamp and its screw so that all cords are not some tension pulled and pulled off.
K28DSM2NET K35DSM2NET K40DSL2NET K40DSH2NET K45DST2NET
(The illustration shows an example of connecting for high power operation. For low power operation, connect cords according
to the "Wiring Diagram" on page 11.)
X
Terminal
Nylon clamp
Power cord:
connected by electric technician
K40DTL2BET K40DTH2BET K45DTT2BET K45DTH2BET
(The illustration shows an example of connecting for high power operation. For low power operation, connect cords according
to the "Wiring Diagram" on page 11.)
X
Terminal
Nylon
clamp
Power cord:
connected by electric technician
After connection
Shut the terminal cover and tighten the screws.
At that time, carry out with much care against the
terminal cover biting power cord.
Head Office : 4017, Takaki-cho, Kasugai, Aichi, Japan
Terminal: For reference only
(Sold at parts stores.)
Note: Don't loosen
these screws.
(from inside)
Power cord:
connected by
production
Note: Don't loosen
these screws.
(from inside)
Power cord:
connected by
production
KDK Company, Division of PES
It is required to use terminal (Not included)
that complies IEC60998.
Red
White
Black
Fan
body
Power cord treatment
Power cord
(2 x 0.75mm
)
2
Power cord treatment
Power cord
(3 x 0.75mm
2
)
Terminal screw
Terminal
Power cord
(1)
X Section
The tip of the power cord which is not used must
be insulated.
unit : mm
It is required to use terminal
(Not included) that complies
IEC60998.
6
40
unit : mm
It is required to use terminal
(Not included) that complies
IEC60998.
6
40
1. Twist the power copper wire
once and plug it into the
terminal socket.
Spring plate
2. The power cord leads must not
become separated or exposed,
and should not come in contact
Copper wire
with other cords.
3. Securely tighten the terminal
screws.
Printed in Thailand
K25DSF2921 NET
T0913-0