11. Turn on water supply and check for leaks. Release air
from tank by interrupting infrared beam; a steady stream of
water assures all air is removed. The sensor has a 30
second maximum ON time. It may be necessary to step away
from beam a few times to allow chiller tank to fill.
DO NOT SOLDER tubes while
inserted into the strainer as
damage to o-rings may result.
12. These products are designed to operate on 20-105
PSIG supply line pressure. If inlet pressure is above 105
PSIG, a pressure regulator must be installed in the supply
line.
Any damage caused by connecting
these products to a supply line with
pressure lower than 20 PSIG or
higher than 105 PSIG IS NOT
covered under warranty.
13. Make electrical connections to the chiller. See chiller
instructions.
14. Check stream height from bubbler. Stream height is
factory set at 35-40 PSI. If supply pressure varies greatly
from this, please do the following. For Pushbar units only,
remove items 2, 19, and 20 (push arm and the bottom and
the top actuator plates – Figure 20) by removing the screws
holding assembly together and adjust the screw on the
regulator (Item 14 – Figs. 21 & 22). Clockwise adjustment will
raise stream height and counterclockwise movement will
lower stream height. For Electronic sensor units only,
remove bottom access panel and turn adjustment screw on
the regulator (Item 14 - Figs. 25 & 27). Clockwise adjustment
will raise stream height and counterclockwise movement will
lower stream height. For best adjustment, stream height
should be approximately 1-1/2" (38mm) above the bubbler
guard. (See Figure 16).
15. Mount lower panel. Loosen the two (2) #10-24 x 5/8"
(16mm) screws at frame bottom lip. Slide upper tongue of
lower panel under lower edge of already installed upper
panel. Tighten previously loosened screws securely.
16. Replace bottom access panel to fountain basin using
screws provided. Tighten securely.
Figure 15 – Lower Panel Installation
OVLEREEQ*G OVLSREEQ*G OVLESREEQ*G OVLSEREEQ*G
Figure 16 – Stream Height
37
35
CHILLER
OUTLET
Figure 17 – OVL-II EREE-Q/SREE-Q Tube Routing
37
36
CHILLER
OUTLET
Figure 18 – OVL-II SEREE-Q/ESREE-Q Tube Routing
9
37 - TO
BUBBLER
37
CHILLER
34
INLET
37 - TO
BUBBLER
37
37
34
CHILLER
INLET