5.
Install the frame assembly squarely in wall opening
with frame upright support edges flush with the finished wall
face. Secure the frame to the wall through holes with (12)
5/16" bolts or screws (not provided). Tighten securely.
NOTE:
Be sure that frame is squared in location. Do not
use less than required screw quantity and size.
MODEL
OVL-ESREE
OVLEREEQ*G OVLSREEQ*G OVLESREEQ*G OVLSEREEQ*G
MODEL OVL-SEREE SHOWN
Legend
Item
A
1/4" O.D. Tube - Water Outlet Connection
B
3/8" O.D. Tube - Water Inlet Connection
C
1-1/4" O.D. Waste Tube
D
Electrical Inlet on Chiller
E
Electrical Outlet Location. Additional UL/CSA listed grounded outlet (By others)
required for 115 Volt, 60Hz.
Figure 8 – OVL-II SEREE-Q/OVL-II ESREE-Q Rough-In Dimensions
6.
Attach the chiller shelf support rods to the right side of
the frame uprights at the second set of holes counting from
the bottom and to the shelf at the (2) side holes. Line up the
other shelf holes with the frame bottom holes and fasten the
assembly to the wall opening using appropriately sized
screws or bolts and nuts (not provided).