MASTERBUS SETTINGS

7.11 EVENTS

Event x source
See section 7.11.1 and 7.11.2
Event x
Select a connected MasterBus device that should take
target
action due to a Mass Charger event.
Event x command
Action to be taken by the target device.
Event x data
Data is linked to the command. See also figure 10.
Event x+1
The next event appears after enabling Event x.

7.11.1 Mass Charger event source list (Mass Charger as event source)

Charging
Bulk
Absorption
Float
Failure
CSI
Equalize
TC Error
Fan
LED Bulk
LED 20-40
LED Abs
LED 60-80
LED Float
LED Failure

7.11.2 Mass Charger event target list (Mass Charger as event target)

Mpc reduce
Mpc off
Bulk
Absorption
Float
On/ Standby
20
Mass Charger state is On
State of charge is Bulk
State of charge is Absorption
State of charge is Float
Charger failure MasterBus alarm
Charger Status Interface MasterBus alarm to sound a horn at charger failure
Mass Charger is in Equalize mode
Battery temperature sensor error
MasterBus signal for an external fan to start (at 50% load / 50°C)
LED Bulk illuminates
LED 2 illuminates (see figure 3)
LED Abs illuminates
LED 4 illuminates (see figure 3)
LED Float illuminates
LED Failure illuminates
Command to reduce AC current at a 5%/sec rate
Command to reduce AC current fast
Command to start the Bulk state of charge
Command to start the Absorption state of charge
Command to start the Float state of charge
Command to switch on the Mass Charger
July 2010 / Mass Charger 12/60-2; 12/80-2; 24/50-2; 24/75; 24/100; 3-24/100; 48/25; 48/50 / EN
Disabled
Select...
Select...
Off
Disabled
Figure 10 shows the meaning of the event data.
Input (pulses)
The input is represented by an on/off switch.
Output (data)
On changes the status to On at the first signal.
Off changes the status to Off at the first signal.
Copy lets the status follow the input.
Copy Invert lets the status follow the opposite of the input.
Copy is used for dimming too by holding the pulse switch
pressed for a longer time.
Toggle changes the status at the first signal and back at
the second signal. It is used in combination with a pulse
switch.
Figure 10: Event data
Selectable targets are
system dependent.
See command list in
selected device manual
Off, On, Copy, Copy
Invert, Toggle.
See Event x.