calibrate the device.
After calibration, the Optimal and High values will be automati-
cally set. See the Section Optimal Value and High Value below
for instructions to manually adjust the Optimal and High values
respectively.
Hard Calibration
Use the <CALIBRATE> menu to perform a hard calibration upon
first power-up, after a factory-reset, or after physical changes
to do a reset. While device is off, hold up and down and press
power. Contiue holding until reset done. This deletes all shots but
needs to be done if replacing sensor or changing bows:
• Navigate to <CALIBRATE>
• Relax the bow strings and keep steady
• Hold [Select] until the display changes
• Wait until the display shows "Fire Shot"
• Shoot an arrow as you normally would
• The <ACTIVE> screen should be shown
Soft Calibration/Tare
This zeros the bow for current conditions, weather/equipment
change etc. This does not delete any settings and only zeros the
bow. If the active screen is off more than +5 or -5, it is important
to calibrate/tare. Like a weight scale, whatever this value is off at
static will be off at full draw. You must hold the bow exactly the
same each time you calibrate. Use the <CALIBRATE> menu to
perform a soft calibration when the force counts drift:
• Navigate to <CALIBRATE>
• Relax the bow strings and keep steady
• Press [Select]
• Wait until the <ACTIVE> screen is shown

Advertisement

loading

This manual is also suitable for:

Sweepspot pro 2