Download Print this page

Pressure Perfect Products SweepSpot PRO Installation Instructions Manual

Advertisement

Quick Links

www.SweetSpotArchery.com
Installation Instructions

Advertisement

loading

Summary of Contents for Pressure Perfect Products SweepSpot PRO

  • Page 1 www.SweetSpotArchery.com Installation Instructions...
  • Page 2: Installation Of Sensor

    WARNING Installation of Sensor Always inspect your equipment prior to shooting an arrow. Be- (THIS IS THE MOST CRUCIAL PART OF INSTALLING fore you take a shot, know your target and what lies beyond your SWEETSPOT. IF THE SENSOR IS NOT ADHERED CORRECTLY target for safety purposes.
  • Page 3 where the sensor will be mounted with with glue. Tip: more glue is better then FIG. 2 FIG. 4 an alcohol pad. not enough glue. (See Fig. 4). Step 3) Apply a piece of scotch tape to Step 5) Starting at the bottom where the top of the sensor hanging over so the tape meets the edge of the green that it can be stuck straight and square...
  • Page 4 This forces out any air bubbles and FIG. 5 keeps the sensor secure while it cures Step 8) If you wish to remove the electrical tape, wait 24 hours. (this tape can be removed in 24hrs It is recommended to leave the tape on to protect the sensor. It after the glue has completely cured) is also highly recommended, after the cable is plugged into the (see Fig.
  • Page 5 controller to your sight rod or bow riser. Be sure the cable housing. Some scope setups allow you to mount the LED from the sensor will reach the sensor port without damaging card directly behind the level, which will brighten the level the wire.
  • Page 6 Optimum Setting sure no wires interfere with any moving parts and will not inter- WiFi: this will change fere with the arrow leaving the bow. (Pressure Perfect Products Shot Counter from a W to an A when connected to device is not responsible for misuse or improper installation.)
  • Page 7 ditions (uphill, downhill, temperature change, stabilizer or any SweetSpot PRO Software change to strings or cables). Like a weight scale, whatever Definitions this is off at static will be off at full draw. • Press: Press button down briefly then release •...
  • Page 8 calibrate the device. • Shoot an arrow as you normally would • The <ACTIVE> screen should be shown After calibration, the Optimal and High values will be automati- cally set. See the Section Optimal Value and High Value below Soft Calibration/Tare for instructions to manually adjust the Optimal and High values This zeros the bow for current conditions, weather/equipment respectively.
  • Page 9 Active Screen respectively After a calibration, the <ACTIVE> screen will show. • Press [Select] to apply • Force counts • High counts High Value • Navigate to <HIGH VALUE> • Last shot counts • Press [Select] to begin adjustment • Optimal counts •...
  • Page 10 • Hold [Left] or [Right] scroll through past shots faster • Press [Select] to begin adjustment • Press [Select] to end viewingUse the <SHOTS FIRE> menu • Press [Left] or [Right] to decrement or increment respectively to clear all shots: •...
  • Page 11 Optimal and High LED Brightness used for public access. Use the <BRIGHTNESS OTHER> menu to set the brightness of • See Section Settings Page for router setup the Pin LED: • OFF: The WIFI is turned off to save battery life. •...
  • Page 12 • Use password to connect to device • Use the SSID and Password to connect to the WIFI • Open the homepage 10.0.0.1 in an internet browser To generate a new AP Password: Note: The device’s date and time is automatically synced to your •...
  • Page 13 • Release Buttons Webserver Note: The WIFI SSID, password, and channel do not get reset on The built-in webserver has the following functions: a factory-reset. • View and Save past shots Shot Marked By Archer (Press Select • View real-time force Shot Broke Above High Value On Active Screen to Mark Shot) •...
  • Page 14 Force Graph Plotted every 250 milliseconds, allowing you to see and review your shot from start to finish.

This manual is also suitable for:

Sweepspot pro 2