Mounting - Grundfos CUE Series Installation And Operating Instructions Manual

Table of Contents

Advertisement

5.4 Mounting

5.4.1 Mounting the drip shield
To comply with the IP21 rating, a separate drip shield is to be
fitted:
1. Remove the two screws. See fig. 6.
2. Fit the drip shield.
3. Fit and tighten the screws to 5.6 Nm.
Fig. 6
Fitting the drip shield
5.4.2 Mounting on the wall
The user is responsible for mounting the CUE
Caution
securely on a firm surface.
See the main dimensions and weights in section
Note
16.2.
1. Mark the mounting holes on the wall using the drilling
template. See fig. 2.
2. Drill the holes. See fig. 7.
3. Fit the screws at the bottom, but leave loose. Lift the CUE up
on the screws. Move the CUE against the wall, and fit the
screws at the top. Tighten all four screws. See fig. 3.
Fig. 7
Drilling of holes in the wall
6
b
a
a
b
5.4.3 Mounting on the floor
Warning
The CUE is top-heavy and may fall over if the
pedestal is not anchored to the floor.
The user is responsible for mounting the CUE
Caution
securely on a firm surface.
See the pedestal kit instructions for further
Note
information.
By means of a pedestal (option), the CUE can also be mounted
on the floor.
1. Mark the mounting holes on the floor. See fig. 8.
2. Drill the holes.
3. Mount the pedestal on the floor.
4. Mount the CUE on the pedestal using the enclosed screws.
See fig. 9.
Back
Front
Fig. 8
Drilling template for pedestal [mm]
Fig. 9
CUE on a pedestal

Advertisement

Table of Contents
loading

Table of Contents