Technical Functional Overview - Wohler AMP1A Series User Manual

1 ru, analog audio monitors with level meters
Hide thumbs Also See for AMP1A Series:
Table of Contents

Advertisement

A M P 1 A S e r i e s U s e r G u i d e
T e c h n i c a l F u n c t i o n a l O v e r v i e w

Technical Functional Overview

8 2 1 0 2 0 :
A M P 1 A S er ie s U s e r G u i d e
22
© 2 0 1 0 Wo h l e r Tec h n o l o g i e s , I n c. A l l r i g h t s r e s er ve d .
Figure 1–18
Meter Input Gain Calibration Settings
DIP switch sections S1 and S2 set the meter input gain calibration,
which determines the level of the input signal that will result in a "0"
reading on the meter bar graphs. The factory setting is +4 dBv, but can
instead be set for -6 dBv, 0 dBv, or +8 dBv by the user.
Bar Graph Display Modes
DIP switch sections S3 and S4 determine how peak levels are displayed
(display mode) and select either the "PPM" mode or an auto-reset "VU
Peak" mode (not the PPM value!). The PPM mode exhibits an attack
time of 10 milliseconds and a decay time of 2 seconds from 0 to -20 dB.
The VU mode exhibits a 300 millisecond rise to 99% of full indication
and a decay of 300 milliseconds. The factory setting is VU mode.
Figure 1–19 on page 23
overall functionality of the AMP1A Series monitors.
Meter Input Gain Calibration and
Display Mode DIP Switch Settings
through
Figure 1–22 on page 26
illustrate the

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Amp1a-30Amp1a-plusAmp1a-106Amp1a-lp10s

Table of Contents