Connecting the device

3.4.1

Notes on connection

Requirement
● The device has been installed according to the information provided in these operating
instructions.
● Ensure only shielded data cables are used for operation, as described in the section
Accessories (Page 23).
Connection sequence
Connect the device in the following sequence:
1. PE conductor
2. Power supply
Perform a power-up test to ensure the power supply is connected with the correct
polarity.
3. PC
4. I/Os if needed
Note
Damage to the device
Failure to adhere to the connection sequence can damage the device.
Make sure you connect the device according to sequence listed above.
You disconnect the device in the reverse order.
Connecting the cables
When connecting the cables, make sure that you do not bend the contact pins.