Installing and connecting the device

3.2 Installing the built-in unit

3.1.3

PRO devices

3.1.3.1

Permitted mounting positions

The device is intended for mounting on a support arm or stand.
The figure below shows the permitted mounting positions and the associated ambient
temperatures using a device for stand mounting as an example.
3.2
Installing the built-in unit
3.2.1

Notes on installation

Before installing the device, please ensure that the installation location complies with the
following:
Risk of fire
The device is classified for use as "Open Type" according to UL508 in the Industrial Control
Equipment sector. In the event of overheating, the device may discharge burning materials
that can cause a fire.
Keep in mind:
• Requirement for approval and operation of the device according to UL508 is its
• Install the device in an enclosure that meets the requirements of paragraphs 4.6 and
40
WARNING
installation in a UL508-compliant enclosure.
4.7.3 of the standards IEC/UL/EN/DIN-EN 60950-1.
Industrial Flat Panel IFP1500, IFP1900, IFP2200, IFP1900 PRO, IFP2200 PRO, IFP1900 ETH, IFP2200 ETH
Operating Instructions, 07/2016, A5E31298376-AF