Troubleshooting, Maintenance; No Display - UseTECH FlowTimer+ Protect Set Operating Manual

Hot water shut-off valve for the flowtimer+ system
Table of Contents

Advertisement

Troubleshooting, Maintenance

9
Troubleshooting, Maintenance
9.1

No display

03/19
Power failure
 In the event of a power failure, the FlowTimer+ Protect
opens automatically and connects the downstream piping
system to the hot water supply.
The protective function is then no longer given!
If the FlowTimer+ Protect does not display a status, make sure that
the power supply is working and that the power supply is plugged
in. If there is still no display, the system must be restarted.
 Disconnect power supply and wait approx. 30 seconds.
 Reconnect power supply unit
 The status display shows the system restart.
Possible cause
A fault in the power supply has switched off the FlowTimer+
Protect. If this error occurs repeatedly, consult a qualified
technician.
FlowTimer+ Protect Set