Mounting The Electronic On The Shut-Off Valve - UseTECH FlowTimer+ Protect Set Operating Manual

Hot water shut-off valve for the flowtimer+ system
Table of Contents

Advertisement

Installation
6.4

Mounting the Electronic on the Shut-off valve

03/19
The FlowTimer+ Protect electronic (3) is firmly screwed to
the solenoid coil (15) and forms a unit which must never be
separated (loss of warranty).
To mount the FlowTimer+ Protect on the shut-off valve, the
solenoid coil (15) is placed on the armature tube of the valve (4).
Then press briefly and forcefully on top of the solenoid coil (not on
the electronics) until the coil audibly engages in the holder. Thus
the coil is mounted correctly.
The supplied O-ring between valve body and coil is important. In
case of loss or defect, please contact our customer service.
To disassemble, push one or two screwdrivers between valve body
(2) and solenoid coil (15). Then lever the coil away from the valve
body. This requires a little more force than the previous pressing.