INSTRUCTIONS FOR THE INSTALLER
ELECTRICAL CONNECTION
WARNING! THIS APPLIANCE MUST BE EARTHED!
Your cooker should have been checked to ensure that
the voltage corresponds with the supply voltage, this is
stated on the rating plate, which is situated on the rear
of the cooker. The cooker must be connected by a
qualified electrician to a suitable double-pole control unit
with a minimum of 32A and a minimum contact
clearance of 3mm, which should be fitted adjacent to
(but not above) the cooker, in accordance with IEE
regulations. The power supply cable should conform to
BS6004. We recommend P.V.C. insulated twin and earth
cable with a conductor size of 6mm2 .. The control unit
should be easily accessible in the event of an emergency.
This appliance conforms to EN55014 regarding
suppression of radio and television interference.
Allow sufficient cable length for the cooker to be pulled
out for cleaning, but do not let it hang closer than 50mm
(2") to the floor. The cable can be looped if necessary,
but make sure that it is not kinked or trapped when the
cooker is in position.
L
G83
L N
N
FIG.5
Before you cook for the first time, we recommend that
you switch on each element in turn to burn off any odours
remaining from
manufacture. Simply operate the grill on maximum for
a few minutes, and the oven for approximately 30
minutes. Ensure that the room is well ventilated (eg.
open a window or use an extractor fan) and that persons
who may be sensitive to the odour avoid any fumes. It
is suggested that any pets be removed from the room
until the smell has ceased.
Connection to the mains terminal block as shown below.
It is accessed by removing the cooker back panel.