Fitting the column

The column and display head are fitted to the weighing platform.
– Guide the connecting cable through the
opening.
– Place the column in the recess. The
display should be legible for people
standing on the scale.
– Screw the column to the weighing plat-
form from underneath.
– If necessary, lay the scale carefully on
its side to tighten up the screws.
– Connect the plug of the connecting
cable to the rear of the scale.
– Then place the scale upright again.

4. Setting up and aligning the scale

– Place the scale on a level surface.
– Unfix the locknuts above the four foot
screws (1).
– Align the scale by screwing the foot
screws. The air bubble in the spirit level
must be right in the centre of the
circle (2).
– Then re-tighten the locknuts (3).
– Ensure that only the feet of the scale are
in contact with the floor. The scale may
not be in contact at any other point.
Important!
The alignment of the base of the scale
must be checked and corrected if nec-
essary every time the location of the
scale is changed.