Summary of Contents for Seca 745

  • Page 1 745 seca 725...
  • Page 2 Bedienungsanleitung und Garantieerklärung ..3 Instruction manual and guarantee ....25 Mode d’emploi et garantie ......45 Manuale di istruzioni e garanzia .
  • Page 3: Table Of Contents

    4.3 Information on the (seca 745) ....42 packaging ....32 11.
  • Page 4: Full Certification

    By purchasing this mechanical baby scale you are now in possession of an extremely accurate yet robust device. seca has put its experience at the service of health care for over 170 years and as a market leader in many countries, is constantly setting new standards with its innovative developments for weighing and measure- ment.
  • Page 5: Intended Use

    English 2.2 Intended use The seca mechanical baby scale is mainly used in hos- pitals, doctors' surgeries and inpatient care facilities in accordance with national regulations. The scale is both for determining birth weight and checking weight gain during the growth process, and it supports the doctor supervising treatment in making a diagnosis or deciding on a treatment.
  • Page 6: Safety Information

    3. SAFETY INFORMATION 3.1 Safety information in these instructions for use DANGER! Used to identify an extremely hazardous situa- tion. If you fail to take note of this information, serious irreversible or fatal injuries will occur. WARNING! Used to identify an extremely hazardous situa- tion.
  • Page 7: Avoiding Infections

    English seca service partner. • Only use original seca accessories and spare parts, otherwise seca will not grant any warranty. Avoiding infections WARNING! Risk of infection • Hygienically reprocess the scale regularly as described in the respective section in this document.
  • Page 8: Handling The Measurement

    Inconsistent measuring results • Before you save measurement values deter- mined using this device and use them further (e.g. in seca PC software or in a hospital infor- mation system), make sure that the measure- ment values are plausible. • If measurement values are transmitted to seca...
  • Page 9: Overview

    English 4. OVERVIEW 4.1 Controls seca 745/725 Control Function Can be moved to set the weight display roughly Large sliding weight • Pull forward: release sliding weight • Release: lock sliding weight in position Can be moved to set the weight display...
  • Page 10: Information On Device And On Rating Plate

    Control Function Indicates whether the device is horizontal Spirit level (verified models) • 4 pcs Device feet • Adjustable to align the scale accurately (verified models) 4.2 Information on device and on rating plate Text/symbol Meaning Model Model number Ser. No. Serial number Follow instructions for use Conformity label according to Directive 2009/23/EC gov-...
  • Page 11: Before You Get Started

    English Permitted min. and max. temperature for transport and storage Permitted min. and max. moisture for transport and storage Packaging material can be disposed of through recycling programs 5. BEFORE YOU GET STARTED … 5.1 Scope of supply Component Qty. Scale Tray User manual, not illustrated...
  • Page 12: Put On Tray

    5.3 Put on tray 1. Place the tray centrally on the scale. 2. Ensure that the locking levers for the tray engage in the openings in the housing. 3. Push the locking levers down. The tray is attached to the housing. 5.4 Set up and align scale NOTICE! Incorrect measurement due to force shunts...
  • Page 13: Operation

    English 6. OPERATION 6.1 Rendering the scale operational Releasing/locking the The beam must be locked in position when the device is transported and when the tray is to be placed on the beam housing. The beam must be released before weighing. Push the locking lever upwards.
  • Page 14: Balancing The Beam

    Balancing the beam 1. Ensure that both sliding weights are in the “0” position. 2. Undo the knurled screw on the tare weight. 3. Move the tare weight to balance the beam. 4. Wait until the beam has stopped swinging. NOTICE! Incorrect measurement due to force shunt If you touch the scale, weight will not be...
  • Page 15: Weighing

    English 6.2 Weighing CAUTION! Risk of falling, faulty operation To prevent falls from the scale and faulty opera- tion, you must ensure before each use that the scale is operational. – Ensure that the tray is correctly fixed in position (see “Put on tray” on page 34). –...
  • Page 16: Taring Additional Weight

    5. Move the small sliding weight until the beam is bal- anced exactly. Pointer and counterpointer must be at exactly the same level. 6. Wait until the beam has stopped swinging. NOTICE! Incorrect measurement due to force shunt If you touch the scale, weight will not be measured correctly.
  • Page 17: Hygiene Treatment

    English 7. HYGIENE TREATMENT NOTICE! Damage to device Inappropriate detergents may damage the sensitive surfaces of the device. – Do not use caustic or abrasive detergents. – Do not use spirits or benzine. 7.1 Cleaning Use a soft cloth dampened with mild soapsuds to clean the surfaces of the device.
  • Page 18: Function Check

    “What do I do if ...” in this document, you may not use the device. – Have the device repaired by seca service or by an authorized service partner. – Follow the section entitled “Servicing/ recalibration”...
  • Page 19: What Do I Do If

    3 to 5 years. NOTICE! Incorrect measurements as a result of poor servicing – Have servicing and repairs carried out exclusively by seca service or by an authorized service partner. What do I do if …? • 41...
  • Page 20: Information On Servicing And Subsequent Verification (Seca 745)

    10.2 Information on servicing and subsequent verification (seca 745) We recommend having your device serviced prior to subsequent verification. NOTICE! Incorrect measurements as a result of poor servicing – Please only have servicing and repairs performed by an authorized service partner.
  • Page 21: Weighing Data

    English General technical data seca 745/725 Ambient conditions, transport • Temperature -10 °C to +65 °C (14 °F to 149 °F) • Air pressure 700 - 1060 hPa • Humidity 0 % - 95 %, no condensation Medical device in accordance with...
  • Page 22: Warranty

    The warranty shall become null and void where the device is opened by persons not expressly authorised to do so by seca. We ask customers based abroad to contact their local sales agent directly in the case of warranty claims.

This manual is also suitable for: