Contents Important information Installation Concerning this documentation 3 System requirements 17 11 Warnings and symbols 3 Installation 18 12 Copyright and property rights 71 Assembling the handpiece holder 18...
Page 4
Contents Appendix 14 Information concerning EMC in ac- cordance with IEC 60601-1-2 30 141 General information 30 142 Abbreviations 30 143 Guidelines and manufacturer dec- laration 31...
Wear protective gloves was sold Air Techniques cannot be held liable and CE mark cannot offer guarantees for safe and smooth operation of this unit if notes and...
2.1 Indication for use / al of Air Techniques Intended use The camera handpiece of the CamX Triton HD can be used in combination with a variety of in- terchangeable heads This enables different ap- plications Possible applications: –...
Before each use check the function and con- and repair work must be carried out either by dition of the appliance Air Techniques personnel or by a suitably Do not convert or change the appliance in any qualified person approved by Air Techniques...
Handpiece holder with USB hub J2560 NOTICE Negative effects on the EMC due to non-authorized accessories Only Air Techniques accessories or ac- cessories approved by Air Techniques may be used If other accessories are used, observe...
O-ring (2 pieces) J2570 tion): Part no. As sold Cam interchangeable J2610 non sterile head for CamX Triton HD Spectra interchange- J2710 non sterile able head for CamX Triton HD Handpiece holder for...
Product description Technical data 4.1 Handpiece Electrical data Voltage V DC 475 - 525 Signal output USB 20 Type of protection IP20 Protection class Applied part Type BF Operating mode* T1/T2 = 27% 15 min / 55 min (switch-on/-off time) At an ambient temperature of max 104 °F and while observing the switch-on/off time, the hand- piece reaches a maximum surface temperature of 140 °F Classification Medical device (IEC 60601-1)
Product description 4.4 Handpiece holder with USB hub (optional) Electrical data Nominal voltage V DC General technical data Dimensions (W x Hx D) 228 x 327 x 484 Weight Power supply type Manufacturer GlobTek Inc Model GTM41076-0612-XX Electrical data of power unit Nominal voltage V AC 100 - 240...
Product description 4.5 Ambient conditions Ambient conditions during operation Temperature °F 50 to 104 Rel humidity 20 to max 75 Air pressure inHg 2067 - 3130 Ambient conditions for storage and transport Temperature °F -13 to +158 Rel humidity 10 - 95 Air pressure inHg 2067 - 3130...
Product description Function 4.6 Model identification plate The model identification plate is located on the The intraoral camera consists of a handpiece cable: and various interchangeable heads The func- tion of the camera depends on the function of the interchangeable head The interchangeable head is recognizable from the symbol on the rear 4.7 Evaluation of conformity...
Product description 5.1 Cam interchangeable head The interchangeable head is plugged onto the handpiece and connected via the contacts A guide prevents incorrect placement of the inter- changeable head On each side of the handpiece there are two buttons: the focus button and the capture but- ton The pressure point of the buttons is notice- able The focus button is used to focus the camera...
Product description 5.2 Spectra interchangeable head Application areas of the Spectra interchange- able head: – Detecting plaque and tartar – Detecting caries at an early stage - Fissure caries that are difficult to detect - Precise location of carious lesions on smooth surfaces - Optically-supported check during excava- tion...
Product description 5.4 Handpiece holder with USB The color scale provides information on carious lesions: hub (optional) The camera can also be connected with the Healthy tooth enamel computer via the handpiece holder with USB hub This makes it possible to have a greater Early-stage caries, incipient enamel distance between the camera and computer caries...
Installation System requirements CPU: ≥ Intel Core i3 RAM: ≥ 4 GB Operating sys- Microsoft Windows 7, 32-bit (Home Premium and higher) tems: Microsoft Windows 7, 64-bit (Home Premium and higher) Microsoft Windows 8, 64-bit (not Windows RT) Microsoft Windows 10, 64-bit (Pro and higher), compatible with DBSWIN ver- sion 510 or higher Microsoft Windows Server 2012 Hard disk:...
Installation Installation Initial start-up 7.1 Assembling the handpiece NOTICE holder Short circuit due to build up of con- densation The handpiece holder can be attached using the Do not put the appliance into operation adhesive or screws until it has warmed up to room temper- Use suitable mounting materials ature and it is dry Mount the handpiece holder near to where the...
Start DBSWIN In the menu select Options > Show Configu- Start VistaConfig via Start > All Programs > ration Air Techniques > VistaEasy > VistaConfig The Configuration tab opens The camera is detected and activated auto- matically Click on the Modules ...
Installation Acceptance tests 8.4 Connect the handpiece holder with the USB hub (optional) 9.1 Electrical safety check Carry out an electrical safety check according to all national regulations Document the results The interchangeable heads in the various versions (see "5 Function") are applica- tion parts in accordance with IEC 60601- USB connection (for camera or USB stick) USB connection (for camera or USB stick)
10 Handling Attaching the interchangeable head Prerequisite: – The handpiece and interchangeable head are NOTICE completely dry Damage to the camera by dropping or scratching Slide the interchangeable head onto the hand- piece (rotate if necessary) until it engages Always store the camera in the hand- piece holder A guide on the handpiece ensures that the interchangeable head can only be placed on...
10.2 Using the disposable protective Hold the disposable protective cover firmly at the white edge and pull off the transparent cover plastic side in the direction of the camera head WARNING There is a danger of cross-contam- ination when disposable protective covers are not used or are used more than once Do not use the appliance without fitting...
10.3 Recording an image with the 10.4 Recording an image with the Cam interchangeable head Spectra interchangeable head Still images and video can be recorded with the When imaging with the Spectra interchangeable camera The possible recording modes are de- head, two views are possible in the imaging pendent on the imaging software software...
Page 26
Putting on the spacer Place the camera with spacer onto the corre- sponding tooth WARNING Danger of cross-contamination when used without preparation or following incorrect preparation Sterilize the spacer in the steam steril- izer (see "113 Preparing the spacer") before each use Place the spacer onto the interchangeable head from above Make sure that the spacer does not cover the optical element of the in-...
10.5 Switching off the camera Analysis The prophylaxis view shows the original image If the camera is not moved, it automatically Red areas indicate caries-causing bacteria The switches itself off after the set stand-by time healthy tooth enamel is shown as green areas (preset 2 minutes) When the camera is placed in the handpiece holder, it is immediately switched off...
Clean the window of the optic itself of the in- For cleaning and disinfecting CamX products, terchangeable head from outside using the Air Techniques recommends Monarch disinfect- microfiber cloth with a drop of alcohol ing wipes For a full list of approved cleaning chemicals, contact Air Techniques 11.1 Clean and disinfect the hand-...
Dry clean the lens in the handpiece with com- Steam sterilize the spacer in a gravity steam pressed air or with a cotton bud sterilizer at 250 °F for 30 minutes and dry time of 20 minutes before use Use a new replacement spacer as needed Storage Store the product protected against contami- nation...
Troubleshooting 13 Tips for operators and service technicians Repairs, above and beyond standard maintenance, may only be carried out by a suitably quali- fied technician or one of our service technicians Problem Probable cause Solution Disposable protective cover not Place the disposable protective Image cloudy, milky placed correctly on the window of cover correctly on the window of...
Troubleshooting Problem Probable cause Solution Moving image judders Computing power of the comput- Reduce the image resolution er too low Use the computer in accordance with the system requirements (E7201) USB driver not up to date Install an up-to-date USB driver Camera is not detected by the software Camera is not correctly...
This information contains excerpts from the international standards for electrical, medical appliances It must be observed during the installation and combination of Air Techniques appliances with prod- ucts made by other manufacturers In the event of uncertainties, the complete standard must be con- sulted 14.2 Abbreviations...
Appendix 14.3 Guidelines and manufacturer declaration Electromagnetic emissions for all appliances and systems The appliance is designed for operation in an electromagnetic environment as specified below The customer or operator of the appliance should ensure that the appliance is operated in such environ- ments Interference emission Compli-...
Page 34
Appendix Electromagnetic interference immunity factor for all appliances and systems The appliance is designed for operation in the electromagnetic environments specified below The customer or operator of the appliance should ensure that the appliance is operated in such environ- ments Interference IEC 60601 –...
Page 35
Appendix Electromagnetic interference immunity factor for appliances or systems that are operated in healthcare facilities Mobile radios should not be used closer to the unit (including the lines) than the recommended safety distance that is calculated according to the formula that applies to the transmission frequency Interference IEC 60601 –...
Page 37
Appendix Recommended safety distances between mobile HF communication appliances and the appli- ance The appliance is designed for operation in the electromagnetic environments, in which the HF distur- bance variables are checked, specified below The customer or the operator of the appliance can help to prevent electromagnetic interference by maintaining the minimum distances between mobile HF communication equipment (transmitters) and the appliance, as recommended below according to the maximum output line of the communication equipment...
Appendix 14.4 Calculation table If the measured values deviate from the standard values, the values are specified in chapter "4 Tech- nical data" The safety distances can then be calculated in the tables shown below Rated power of the transmitter in Watts (W) in accordance with the specifications of the transmitter manufacturer Compliance level for the test according to IEC 61000-4-6 Compliance level for the test according to IEC 61000-4-3...
Page 40
For over 50 years, air techniques has been a leading innovator and manufacturer of dental products. Our priority is ensuring complete satisfaction by manufacturing reliable products and providing excellent customer and technical support. Whether the need is digital imaging, utility room equipment or merchandise, air techniques can provide the solution via our network of authorized professional dealers.
Need help?
Do you have a question about the CamX Triton HD and is the answer not in the manual?
Questions and answers