6. Press the
Sensor adjustment starts.
7. Rotate the adjustment screw of the throttle valve to adjust the
pressure so that it becomes the proper value
•Proper value of negative pressure: -5.4kPa
•Proper value of positive pressure: 15.00kPa
•As the negative pressure changes between ±0.1 and 0.2kPa, adjust so that the intermediate value may become the target pressure.
•Adjust the throttle valve in order of "negative pressure"  "positive pressure"  "negative pressure".
• Status of lamp and buzzer for each pressure value
Positive pressure Negative pressure
~ 8.49
8.50 ~ 9.49
9.50 ~ 10.49
High
10.50 ~ 11.49
11.50 ~ 12.49
12.50 ~ 13.49
13.50 ~ 14.49
Proper
14.50 ~ 15.49
value
15.50 ~ 16.49
16.50 ~ 17.49
17.50 ~ 18.49
18.50 ~ 19.49
Low
19.50 ~ 20.49
20.50 ~ 21.49
21.50 ~ 22.49
22.50 ~ 23.49
23.50 ~
8. Press the
The error is released and the negative pressure control starts.
key.
Pressure is informed with the buzzer and the ink bottle lamp as well as the
screen display.
For the negative pressure, the buzzer stops within the range of ±0.1kPa. For the
positive pressure, the buzzer stops within the range of ±1.0kPa.
JFX500:
Ink bottle lamp
Pressure
~ -4.75
-4.76 ~ -4.85
-4.86 ~ -4.95
-4.96 ~ -5.05
-5.06 ~ -5.15
-5.16 ~ -5.25
-5.26 ~ -5.35
-5.36 ~ -5.45
-5.46 ~ -5.55
-5.56 ~ -5.65
-5.66 ~ -5.75
-5.76 ~ -5.85
-5.86 ~ -5.95
-5.96 ~ -6.05
-6.06 ~ -6.15
-6.16 ~ -5.86.2
-6.26 ~
key.
Ink bottle lamp Buzzer
Sounds
Stops
Stops
Stops
Sounds
* * AD J US T I NG * *
P L E A SE WA I T
PRES SURE
=
UJV500:
Ink bottle lamp
P L E A SE WA I T
- 4 . 0 0 k P a