INSTALLATION INSTRUCTIONS FOR CONvERTING FROM NATURAL GAS (NG) TO
PROPANE GAS (LP). FOR USE wITh SEREFINA™ DIRECT vENT GAS STOvES
KIT CONTENTS
1 ea. Nova SIT LP Regulator Kit (A)
1 ea. LP main burner orifice (B)
1 ea. LP pilot orifice (C)
1 ea. Sticker, LP Conversion (D)
1 ea. Instruction Sheet
TOOLS NEEDED
5/32" Allen Wrench Or T-Handle Wrench
#2 Phillips Screwdriver
1/2" Open End Wrench
f i r e - p a r t s . c o m
Torx T20, Or Flat Screwdriver
Natural Gas to Propane Gas Converion Kits
Cat. No.
Model
h3705
CI1500 GCK LP
h3706
CI2500 GCK LP
A
B
C
Figure 1 - Kit Contents
wARNING
This conversion kit shall be installed by a qualified
service agency in accordance with the manufacturer's
instructions and all applicable codes and requirements
of the authority having jurisdiction. If the information
in these instructions is not followed exactly, a fire,
explosion or production of carbon monoxide may result
causing property damage, personal injury or loss of
life. The qualified service agency performing this
installation is responsible for the proper installation
of this kit and assumes responsibility for this conver-
sion. The installation is not proper and complete until
the operation of the converted appliance is checked as
specified in the manufacturers instructions supplied
with the kit.
Description
CI1500 Gas Conversion Kit, NG to LP
CI2500 Gas Conversion Kit, NG to LP
THIS APPLIANCE HAS BEEN CONVERTED TO:
PROPANE GAS
INPUT BTU/HR – 27,000
MANIFOLD PRESSURE – 10"
ORIFICE SIZE: .061"
CI1500DvF
LB-102159A
D
THIS APPLIANCE HAS BEEN CONVERTED TO:
PROPANE GAS
INPUT BTU/HR – 34,500
MANIFOLD PRESSURE – 10"
ORIFICE SIZE: .0675"
CI2500DvF
LB-102159B
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
506033-81
SEREFINA™ GAS CONvERSION KITS, NG TO LP
Rev. A, 11/2013
AvERTISSEMENT
Cet équipement de conversion sera installé par une
agence qualifiée de service conformément aux instruc-
tions du fabricant et toutes exigences et codes applica-
bles de l'autorisés avoir la juridiction. Si l'information
dans cette instruction n'est pas suivie exactement, un
feu, explosion ou production de protoxyde de carbone
peut résulter le dommages causer de propriété, perte
ou blessure personnelle de vie. L'agence qualifiée de
service est esponsable de l'installation propre de cet
équipment. L'installation n'est pas propre et compléte
jusqu'à l'opération de l'appareil converti est chéque
suivant les critères établis dans les instructions de
propriétaire provisionnées avec l'équipement.
IMPORTANT CANADA
The conversion shall be carried out in accordance with
the requirements of the provincial authorities having
jurisdiction and in accordance with the requirements
of the CAN/CGA B149.1 Installation code.
IMPORTANT LE CANADA SEULEMENT
La conversion devra être effectuée conformément
aux recommandations des autorités provinciales
ayant juridiction et conformément aux exigences
du code d'installation CAN/CGA B149.1.
The burner orifices provided in this kit are only for
use at elevations of 0 to 4,500 feet (0-1372 M) in
Canada. At higher elevations the BTU input must
be de-rated by 4% for every 1,000 feet (305 M) to
maintain the proper ratio of gas to air. If the installer
must convert the unit to adjust for varying altitudes,
a deration information sticker must be filled out by
the installer and adhered to the appliance at the time
of the conversion. Contact your local gas supplier
for deration requirements for your area.
HEARTH PRODUCTS
KITS AND ACCESSORIES
IMPORTANT
1

Advertisement

loading

Summary of Contents for IHP SEREFINA CI1500 GCK LP

  • Page 1 HEARTH PRODUCTS KITS AND ACCESSORIES 506033-81 SEREFINA™ GAS CONvERSION KITS, NG TO LP Rev. A, 11/2013 INSTALLATION INSTRUCTIONS FOR CONvERTING FROM NATURAL GAS (NG) TO PROPANE GAS (LP). FOR USE wITh SEREFINA™ DIRECT vENT GAS STOvES KIT CONTENTS AvERTISSEMENT 1 ea. Nova SIT LP Regulator Kit (A) Cet équipement de conversion sera installé...
  • Page 2: General Information

    GENERAL INFORMATION READ ALL ThE STEPS BEFORE STARTING ThE CONvERSION. INSTALLER NOTICE: ThESE INSTRUCTIONS MUST BE LEFT wITh ThE APPLIANCE. Pull open lower ALL wARNINGS, PRECAUTIONS AND INSTRUCTIONS IN ThE IN- door to access STALLATION INSTRUCTIONS AND CARE AND OPERATION MANUALS Valve Controls PROvIDED wITh ThE APPLIANCE APPLY TO ThESE INSTRUCTIONS.
  • Page 3 c. Lift glass assembly up and out and carefully set aside in a safe place (see Figure 5). Pilot Assembly Burner Orifice Figure 7 - Burner Removed Step 6. Refer to Figure 8 and the instructions provided with the SIT Regulator Conversion Kit.
  • Page 4 Step 9. Remove the burner orifice from the manifold and replace it with the one provided in the kit (see Figure 10). Use pipe joint compound or MILLIVOLT Hood Igniter Rod Teflon tape on all pipe fittings before installing (ensure propane resistant Thermocouple compounds are used in propane applications, do not use pipe joint compounds on flare fittings).
  • Page 5 Step 19. Inspect the burner for proper flame appearance (see Figure Step 13. Adjust the air shutter to the gap indicated in Figure 13. 12). If necessary, adjust the burner air shutter for proper flame Initially, always position the air shutter to the factory setting as shown in appearance.
  • Page 6 - p a r t s . c o m IHP reserves the right to make changes at any time, without notice, in design, materials, specifications, and prices, and also to discontinue colors, styles, and products. Consult your local distributor for fireplace code information.

This manual is also suitable for:

Serefina ci2500 gck lp