Download Print this page

Advertisement

Quick Links

INSTALLATION INSTRUCTIONS FOR FBK-LIN KIT
FOR USE IN ASTRIA ALLUME60TEN AND SUPERIOR DRL4060TEN FIREPLACES
(This Kit is Compatible for One Sided Application only)
INSTALLER: Leave this manual with the fireplace.
CONSUMER: Retain this manual for future reference.
IMPORTANT NOTICE
THIS KIT IS COMPATIBLE WITH ONE SIDED FIREPLACES ONLY.
f i r e - p a r t s . c o m
This kit must be installed by a qualified installer,
service agency, or gas supplier at the time of the
fireplace installation. These instructions must
be used in conjunction with the installation and
operation manual provided with the fireplace.
ELECTRICAL GROUNDING INSTRUCTIONS This appliance is equipped with a three-prong (grounding) plug for
your protection against shock hazard and should be plugged directly into a properly grounded three-prong
receptacle. The appliance must be electrically grounded in accordance with local codes or, in the absence of
local codes, the National Electrical Code, ANSI/NFPA 70-(latest edition). (In Canada, the current CSA C22-1
Canadian Electrical Code.)
TOOLS REQUIRED (not included)
Electric Drill/Driver Gun
Phillips Screwdriver Bits
5/16 Nut Driver
Kit Components
This kit includes 2 (two) blower assemblies with pre installed
magnets, one (1) thermal switch magnetic assembly, one (1) speed
control assembly and these instructions.
900940-00 REV. NC 12/2018
WARNING
Catalog
Model Number
Number
F3783
FBK-LIN
Speed Control
Assembly
WARNING
GENERAL INFORMATION
This blower kit may be used with gas fireplaces listed herein. The
FBK-LIN blower kit is used when unit-mounted variable speed blower
control is desired. The blowers are installed beneath the rear of firebox.
Room air is drawn in through the bottom area of the fireplace, heated
as it passes across the firebox, and discharged through the upper
air exhaust area at the top of the firebox.
ALL WARNINGS AND PRECAUTIONS IN THE INSTALLATION AND
OPERATION MANUAL PROVIDED WITH THE FIREPLACE APPLY TO
THESE INSTRUCTIONS.
HEARTH PRODUCTS
KITS AND ACCESSORIES
Blower Kit
Kit Name
Blower Kit 2 pc.
Blower
Assembly
Thermal switch
Assembly
FBK-LIN

Advertisement

loading

Summary of Contents for IHP FBK-LIN

  • Page 1 This blower kit may be used with gas fireplaces listed herein. The Electric Drill/Driver Gun FBK-LIN blower kit is used when unit-mounted variable speed blower Phillips Screwdriver Bits control is desired. The blowers are installed beneath the rear of firebox.
  • Page 2 Note: The FBK-LIN blower is for application into direct-vent models near the firebox bottom as shown in Figure 4, in order to sense listed on this manual only. The FBK-LIN blower kit can be installed temperature and properly operate. The blowers will be held in before or after fireplace installation.
  • Page 3 (see Figure 10, page 4). 6. Remove twenty (20) screws securing the firebox bottom cover plate be careful not to break the gasket underneath cover plate (Figures 11 and 11a), page 4 7. Proceed to installing blower kit. 900940-00_NC IHP.us.com...
  • Page 4 Screws holding Gasket exposed, the Pan Media (Do not remove) (Qty. 8) Media Burner Figure 9 - Removing Pan Media Figure 11a - Gasket View Remove 20 Screws Holding Firebox Bottom Cover Figure 11 - Removing Firebox Bottom Cover IHP.us.com 900940-00_NC...
  • Page 5 BK-LIN INSTALLATION INSTALLING FBK-LIN Note: While performing the installation, arrange all wires in an orderly fashion as to not to interfere with other amenities installed in the fireplace. Be certain that all wire terminals are securely attached to ter- minals on blower motor and that the screw retaining the green ground wire is tight.
  • Page 6 CPI SWITCH R = RED Y = YELLOW OFF (O) = INTERMITTENT PILOT MODE ON (-) = STANDING PILOT MODE Thermal Switch Circulation Circulation Blower Left Blower Right Speed Controller and ON/OFF Switch Main Power Cord BLOWER (OPTIONAL) IHP.us.com 900940-00_NC...
  • Page 7 OFF (O) = INTERMITTENT PILOT MODE BATTERY HOLDER ON (-) = STANDING PILOT MODE Remove when Using Optional Battery Holder/Receiver ON/OFF Switch Thermal Switch Circulation Circulation Blower Left Blower Right Speed Controller and ON/OFF Switch BLOWER (OPTIONAL) Main Power Cord 900940-00_NC IHP.us.com...
  • Page 8 f i r e - p a r t s . c o m Innovative Hearth Products reserves the right to make changes at any time, without notice, in design, materials, specifications, prices and also to discontinue colors, styles and products. Consult your local distributor for fireplace code information.

This manual is also suitable for:

F3783