Contents: page Declaration of Conformity............... 1. General....................1.1 Application..................1.2 Technical data................... 1.3 Areas of application................1.4 Accessory..................2. Safety....................2.1 Marking of information in the instruction for use......2.2 Danger arising due to non-compliance with safety advice..... 2.3 Safety conscious working ..............2.4 Safety information for owner / operator..........
- In accordance with EG- low voltage specifiactions i.d.F. 93/68/EWG, appendix I - In accordance with EMV 92/31/EWG und 93/68/EWG - In accordance with 2006/42/EG ---------------------------------------------------------------------------------------------------- We the following ZEHNDER Pumpen GmbH Zwönitzer Straße 19 08344 Grünhain-Beierfeld, declare that the wastewater lifting-unit Microboy...
1.General 1.1. Application This operating instruction is valid for the wastewater lifting-unit type MICROBOY. Non-compliance with the operating instructions - in particular with the safety instructions - as well as non- manufacturer modification or use of non-original spare parts will result in loss of guarantee coverage. The manufacturer accepts no liability for damage or injury resulting from incorrect use of the equipment.
1.4 Accessory This unit is ready for plug-in,complete with pressure connection,check-valve and all necessary seals. 2. Safety These instructions for use contain general information, which should be noted when setting up, using and serving the equipment. 2.1 Marking of information in the instruction for use danger symbol in accordance with DIN 4844 - W9, for warnings regarding electrical current the following symbol is used danger symbol in accordance with DIN 4844 - W8...
Immediately after completion of the work all safety and protection coverings should be reinstalled and / or switched on. Before switching the equipment on again the points covered in the section concerning first use of the equipment should be consulted. 2.6 Non-manufacturer modifications and spare part production Modifications or changes to the pump are only allowed after consulting the manufacturer.
Installing of ventilation pipe: The ventilation of the unit is possible either by the integrated carbon filter into the room directly or by an external pipe over the roof.The diameter of this pipe must be 40 mm. In case of external ventilation the integrated carbon filter and ball must be removed.
7. Disturbance,cause and elimination -Disconnect from mains before working! Disturbance Cause Elimination 1. Motor doesn`t turn - no voltage - connect plug - check wall socket and fuse - cutting edge is blocked - remove cover,turn shaft clockwise with screwdriver -inform service at recurrence - motor overloaded - thermical overload stops motor,reset...
With spare part order give please always the investment type with standard number! assembly drawing nomination Article number 11017E2 assembly Assembly unit complete lifting unit 1.10/1.20 Container MICROBOY; complete without pump and 117620 switching device 1.120 O-ring 30x3 117703 1.140 Valve insert PE 117186 1.150 Lip seal 117188 1.160...
Page 11
Appendix 1: Installation example Appendix 2: pump unit...
Page 12
Appendix 3 and 4: overview complete lifting unit...
Page 13
Appendix 5: Switch device Delay time and overdrive time depending on DIP-switch setting delay time overdrive time delay time overdrive time 10 s delay time overdrive time 15 s delay time overdrive time 20 s delay time overdrive time delay time overdrive time 10 s delay time...