Inspection; Daily Inspection - Toshiba V Series Operation Manual

Integrated controller, ethernet module / ds connection module
Hide thumbs Also See for V Series:
Table of Contents

Advertisement

Chapter 6 Maintenance and Inspection

6.1 Inspection

6.1.1

Daily inspection

6
64
Take the following steps in daily inspection.
Front Panel
(1) LED
Check each LED that it is not difficult to see. If it is, clean it with a soft cloth.
Exercise care not to change the switch positions.
(2) Ethernet connector
Check the connector that it is connected as specified in the Manual for Monitoring
and Control Network Installation and Wiring (6F8C0880) and that the cable
connection is normal.
(a) EN711, EN721 (10BASE5)
Check the slide lock that it is tight.
Check that the cable is not about to come off and that it appears normal.
Also check that the cable is fastened with the connector clamp.
Check that the wiring is as specified in the Manual for Monitoring and Control
Network Installation and Wiring as to bends, radius, route, etc.
(b) EN731, EN741 (10BASE2)
Check the BNC connector that it is locked.
Check that the cable is not about to come off and that it appears normal.
Also check that the cable is fastened with the connector clamp.
Check that the wiring is as specified in the Manual for Monitoring and Control
Network Installation and Wiring as to bends, radius, route, etc.
If anything abnormal is found, contact the Toshiba service office concerned.
(c) EN751, EN751A, EN761, FN711
Check that the modular connector is locked.
Check that the cable is not about to come out and that the module has nothing
wrong in its outward appearance. Also check that it has been wired as
described in the Installation and Wiring Manual. (as to bending radius, route,
etc.)
Ventilation holes
Check the front panel and top of the product that the ventilation holes are free of dust and
dirt. If the ventilation holes are clogged up with dust or dirt, remove it with a vacuum
cleaner, for example, then clean them with a soft cloth.
Indoor environment
Check the place where the product is installed that its temperature and humidity meet the
specified temperature and humidity ranges of the product (Table A-1, page 81)
model 3000 Ethernet Module / DS Connection Module Operation Manual