Download Print this page

Eldat RCU01 Series Quick Start Manual page 2

Universal receiver (2-channel)

Advertisement

Programming the Operating Mode
Warning! During program-
ming, the Universal Receiver
is live!
Do not touch the terminals! Only use
suitable tools!
Note:
For each chennel a different operating
mode can be programmed.
1. Select the operating mode via rotary
switch DR1 according to the following
table.
2. Press and hold the programming button
for the desired channel (TA1 or TA2),
until the LED H1 lights up for approx.
1 second.
DR1
Operating Mode
Impulse
0
Relay operates for approx. 1 sec.
1
On/Off (1-Button Operation)
st
1
transmission: Switching on
nd
2
transmission: Switching off
2
Timer 30 Seconds
After transmission, the device is
switched on for 30 seconds. If a
new signal is transmitted within this
30 s period, the 30 s timer is re-
started.
Timer 3 Minutes
3
as for setting 2, but with a period of
3 minutes
4
Memorizing transmission codes
5
Deleting transmission codes
6
Continuous Operation
Relay operates as long as the
transmitter button is pressed.
7
Awning Operation
st
1
transmission: Channel 1
switched on for max. 2 minutes
nd
2
transmission: Channel 1
switched off
rd
3
transmission: Channel 2
switched on for max. 2 minutes
th
4
transmission: Channel 2
switched off
On/Off (2-Button Operation)
9
Transmitter button 1: Switching on
Transmitter button 2: Switching off
Note:
On the operating mode 7 („Awning Opera-
tion") the two channels interact simultane-
ously. Only one of the programming buttons
(TA1 or TA2) has to be pressed in order to
program the operating mode.
Memorizing the Transmission Codes
4 different transmission codes can be
memorized for each channel.
The memory locations for the
transmission codes can be
selected via dip switch S1.
1. Select a memory location via dip switch
S1.
a) Operating Modes 0 to 3, 6, 7
1
Transmitter 1:
OFF
Transmitter 2:
ON
Transmitter 3:
OFF
Transmitter 4:
ON
b) Operating Mode 9
Transmitter
Function
Button
Button 1:
Off
Button 2:
On
Button 3 or
Transmitter 2/
Off
Button 1:
Button 4 or
Transmitter 2/
On
Button 2:
2. Turn rotary switch DR1 to position 4
(„Memorizing Transmission Codes").
3. Press and hold the programming button
for the desired channel (TA 1 or TA2)
until the LED H1 of the receiver flashes.
4. Within the next 10 s, press the transmit-
ter button which is supposed to control
this channel. After memorizing the
transmission code, the LED H1 of the
receiver lights up constantly for approx.
2 s and then turns off. Release the
transmitter button.
5. Repeat steps 1 to 4 for the other trans-
mitters or transmitter buttons.
6. Screw the housing cover back on.
Note:
If a new transmission code is memorized on
a memory location, the old code memorized
on that location is deleted.
Deleting the Transmission Codes
1. Select the memory location to be de-
leted via dip switch S1.
2. Turn rotary switch DR1 to position 5
(„Deleting Transmission Codes").
3. Press and hold the programming button
for the desired channel (TA 1 or TA2)
until the LED H1 of the receiver lights
up. The transmission code on the se-
lected memory location is deleted.
Cleaning the Receiver
Wipe the housing carefully with a damp lint
free cloth.
Caution:
Do not use cleansing agents containing
organic solvents. These are dangerous to
ON
OFF
your health and may damage the surface of
the housing.
Disposal
2
Waste electrical products may not be
OFF
disposed of with household waste!
OFF
Dispose of the waste product via a
ON
collection point for electronic scrap
ON
or via your specialist dealer.
Put the packaging material into the
recycling bins for cardboard, paper
1
2
and plastics.
OFF OFF
Warranty
ON
OFF
Within the statutory warranty period we
undertake to rectify free of charge by repair
OFF
ON
or replacement any product defects arising
from material or production faults.
Any unauthorized tampering with, or modifi-
ON
ON
cations to, the product shall render this
warranty null and void.
Conformity
This product complies with the
essential requirements of the
R&TTE Directive 1999/5/EC.
The Declaration of Conformity can be found
on the Internet at: www.eldat.de.
Customer Service
If, despite correct handling, faults or mal-
functions occur or if the product was dam-
aged, please contact the company at the
address below:
ELDAT GmbH
Im Gewerbepark 14
15711 Zeesen/Germany
Phone: + 49 (0) 33 75 / 90 37-310
Telefax: + 49 (0) 33 75 / 90 37-90
Internet: www.eldat.de
E-mail: info@eldat.de