Instruction For Installation; Gas Connection; Preparing The Appliance; Placing The Appliance - Faber Bright Installation Manual

Table of Contents

Advertisement

UK
IRL

4 Instruction for Installation

4.1

Gas Connection

Installation pipes should be in accordance with BS 6891. Pipe work from the meter to
the appliance must be of adequate size.
The complete installation including the meter must be tested for soundness and
purged as described in the above code.
A means of isolation must be provide in the supply to facilitate servicing. The
connection should be made in 8 mm copper or similar semi flexible tube. (max 1
meter). Ensure that the gas pipe does not interfere with the removal or replacement
of the burner tray or of the controls. The gas connection is nut and olive suitable for
8 mm pipe.
4.2

Preparing the appliance

Remove the packaging and the pallet under the appliance
Determine the position and height where the appliance has to be placed.
Pre-adjust the total height of the appliance considering the desired height (see figure
1.5). There are two ways to adjust the height:
Rough adjustment; by removing the nut and bolt. Shift the leg in steps of
o
30mm and replace the nut and bolt.
Fine adjustment; by adjusting the couple legs.
o
4.3

Placing the appliance

Check paragraph 3.0 before commencing installation
If possible, first place the appliance before assembling the flue
Check if the floor and wall are sufficiently level and perpendicular. If not, you should
fix this
Prepare the gas connection.
Level the appliance.
Assemble the flue system onto the firebox (see appendix C).
4.4

False chimney Breast

Always place ventilation grids in the False chimney Breast (see figure 2.3 - 2.4 and
appendix F).
For the best result keep 300 mm between grid and ceiling.
Build the false chimney around the appliance.
11 <
<
<
<

Advertisement

Table of Contents
loading