Instruction For Installation; Gas Connection; Preparing The Appliance; Placing The Appliance - Faber Honest Installation Manual

Hide thumbs Also See for Honest:
Table of Contents

Advertisement

L
L

4 Instruction for Installation

4.1

Gas connection

Pipe work from the meter to the appliance must be of adequate size.
The complete installation including the meter must be tested for soundness.
A means of isolation must be provide in the supply to facilitate servicing.
Ensure that the gas pipe does not interfere with the removal or replacement of the burner
tray or of the controls.
The gas valve has a connection from 3/8" inner
4.2

Preparing the appliance

Remove the packaging and the pallet under the appliance.
Adjust the total height of the appliance considering the way the appliance will be placed
(see Appendix F). For reasons of transportation the height is pre-adjusted to high.
There are two ways to adjust the height (see fig. 1-1):
Rough adjustment; by removing the nut and bolt. Shift the leg 30mm and replace
the nut and bolt.
Fine adjustment; by adjusting the couple legs
Finally check the explosion lids by visual inspection for closing correctly (the lid covers the
hole and is level).
4.3

Placing the appliance

Always keep minimal 10mm distance between the appliance and the surround to apply a
ventilation gap. By using this ventilation gap the hot convection air can be drained easily
through the surround (see fig. 1-3 till 1-6).
If possible, first place the appliance before assembling the flue
Check if the floor and wall are sufficiently level and perpendicular. Fix if necessary
Prepare the gas connection
Position the firebox in the fireplace opening. Make sure that the appliance is level
Fasten the appliance to the back wall using the four slide able mounting lips on top
and on either side of the appliance